I. Damper Adjustment

See vent graph for recommendations on page 11 before you begin your adjustment. If your installation falls within the range of the gray shaded area of graph, it may be necessary to make an adjustment to the vertical damper to improve the flame appearance in your appliance.

Figure 8.24 Open the right side panel to access the shutter adjustment.

Loosen screws and make adjustment according to vent chart. Make adjustment until flame size and activity suits your personal preference, and then retighten the screws.

NOTE: In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.

J. Shutter Adjustment

NOTE: Do not close so much as to cause a sooty flame. Improper adjustment can cause sooting in the firebox and/or on the outside of a house with a horizontal termination.

After adjustment, tighten nut to lock in place.

K. Glass Replacement

NOTE: Glass can be replaced either as three separate pieces, or as an assembly with the door. See Section 12.

To Replace Separate Glass Pieces

1.Turn off gas to appliance.

2.Remove door from the appliance and set on a protec- tive surface.

3.Remove door crown. See instructions in this manual for installation of door crown for procedure.

4.Remove top and bottom retainer screws from front of door. Set top and bottom glass retainers aside. Loosen side glass retainer screws, but do not remove.

5.Remove glass pieces and discard. Keep aluminum channels for reassembly.

6.Slide replacement side glass into the side glass retain- ers.

7.Place aluminum channels over side glass.

8 Install center glass into aluminum channels.

9.Reinstall glass retainers and screws.

10.Reinstall door crown.

Door Frame with Glass Assembly Replacement

Use only Door Assembly replacement as specified in Section 12 of this manual, available from your dealer, if any glass becomes broken in the Hudson Bay.

Follow the previous instructions to install the door crown and grille to the new Door Assembly.

OPENCLOSE

Figure 8.25 The shutter is located on the underside of the appliance, on the right side. To adjust the shutter, loosen the wingnut.. Retighten the wingnut after adjustment.

Moving the shutter bolt to the right closes the shutter. Moving the shutter bolt to the left, will open the shutter. Opening the shutter causes flames to become shorter and blue. Closing the shutter creates taller orange/yellow flames.

CAUTION

Handle glass assembly with care.

Inspect the gasket to ensure it is undamaged.

Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass assembly as a complete assembly.

10/08

Quadra-Fire • Hudson Bay • 7003-121 Rev. i

Page 33