VINYL SIDING

APPLY SEALANT

TO ALL FOUR

SIDES

SCREWS

BOLT HORIZONTAL

TOP TO VINYL

STANDOFF

 

 

SCREWS

WALL THIMBLE

 

VINYL SIDING

COVER

 

 

 

STANDOFF WITH

 

WALL THIMBLE

SIDING BENEATH

 

REMOVED

 

 

Figure 5.8

WARNING

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

Ensure vent components are locked together correctly.

Pipe may separate if not properly joined.

WARNING

Do NOT connect a pipe section to a termination cap without using the telescoping flue section found on the termination cap.

Step 5.

Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly. It is important that the vent pipe extend into the vent termination cap a sufficient distance so as to result in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the connection between the vent pipe and the vent termination cap by attaching the two sheet metal strips extending from the vent termination cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe section (Figure 5.9).

WARNING

Burn Risk.

Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap.

1/4 in. (6mm)

FOLD STRAP

HERE

SHEET METAL SCREW

WALL THIMBLE COVER/CEILING FIRESTOP AS REQUIRED BY LOCAL JURISDICTION

WALL

THIMBLE

STRAP

Figure 5.9

Note: The attachment from the vent pipe to the vent termination cap must be sealed with silicone. Termination caps shall not be recessed into a wall or siding.

 

 

 

 