![CLEARANCES TO COMBUSTIBLES (UL and ULC)](/images/new-backgrounds/46748/4674811x1.webp)
R
Yosemite Wood Stove
CLEARANCES TO COMBUSTIBLES (UL and ULC)
BA
|
|
|
|
|
|
|
| C2 |
|
|
|
|
|
|
|
| |
| C1 |
|
|
|
| D2 | ||
|
|
|
|
| ||||
| D1 |
|
|
|
|
| Fuel Door | |
|
|
|
|
| side | |||
|
|
|
|
|
|
door side
Alcove
E1 |
|
|
| F1 | |
door side |
| |
|
|
|
F2
E2
Fuel door
side
Vertical
Max Mantel Depth 10" (254mm)
G
H
G
G*
IF SIDE FUEL LOADING DOOR IS NOT USED:
•It must remain in the locked position at all times
•Use clearances for
Horizontal, then Vertical
Horizontal
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
TOP VENT VERTICAL | A | B | C1 | C2 | D1 |
| D2 |
| E1 | E2 | F1 | F2 | G | H |
Single | 12.5(316) | 9(229) | 19.5(495) 25.5(648) 10(254) | 16 (406) 14(356) | 16(406) | 18.5(470) | 20.5(521) | 59(1499) | N/A | |||||
Single | 12.5(316) | 9(229) | 19.5(495) 27.5(699) 10(254) 18 (457) | 14(356) 18(457) | 18.5(470) | 22.5(572) | 59(1499) | N/A | ||||||
Double | 10.5(267) | 7(178) | 19.5(495) 25.5(648) 10(254) | 16(406) | 7 (178) | 16(406) | 11.5(292) | 20.5(521) | 59(1499) | N/A | ||||
Double | 10.5(267) | 7(178) | 19.5(495) 27.5(699) 10(254) | 18(457) | 7 (178) | 18(457) | 11.5(292) | 22.5(572) | 59(1499) | N/A | ||||
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP |
|
|
|
|
| |||||||||
Single | 13.5(343) 10(254) | 19.5(495) | 25.5(648) 10(254) |
| 16 (406) | N/A | N/A | N/A | N/A | 59(1499) | 18* | |||
Single | 13.5(343) 10(254) | 19.5(495) | 27.5(699)10(254) |
| 18 (457) | N/A | N/A | N/A | N/A | 59(1499) | 18* | |||
Double | 11.5(330) | 8(203) | 19.5(495) | 25.5(648) 10(254) |
| 16(406) |
| N/A | N/A | N/A | N/A | 59(1499) | 18* | |
Double | 11.5(330) | 8(203) | 19.5(495) 27.5(699) 10(254) |
| 18(457) |
| N/A | N/A | N/A | N/A | 59(1499) | 18* | ||
|
|
|
|
|
|
|
|
|
| |||||
90O ELBOW OFF TOP OF STOVE THROUGH BACKWALL |
|
|
|
|
|
|
|
|
| |||||
Single | 13.5(343) 10(254) | 19.5(495) | 25.5(648) | 10(254) | 16 (406) | N/A | N/A | N/A | N/A | 59(1499) | N/A | |||
Single | 13.5(343) 10(254) | 19.5(495) | 27.5(699) | 10(254) | 18 (457) | N/A | N/A | N/A | N/A | 59(1499) | N/A | |||
Double | 11(279) | 7.5(191) | 19.5(495) 25.5(648) 10(254) 16(406) N/A | N/A | N/A | N/A | 59(1499) | N/A | ||||||
Double | 11(279) | 7.5(191) | 19.5(495) | 27.5(699) | 10(254) | 18(457) | N/A | N/A | N/A | N/A | 59(1499) | N/A |
ALCOVE - Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed
|
|
|
| Max Depth | Min Width | Min Height |
|
|
| |||
|
| Front Door | 48(1219) | 44(1118) | 54(1372) |
|
|
| ||||
|
| Side | 48(1219) | 56(1422) | 54(1372) |
|
|
| ||||
|
| Side | 48(1219) | 60(1524) | 54(1372) |
|
|
| ||||
Double | 11.5(292) | 8(203) | 19.5(495) | 25.5(648) | 10(254) | 16(406) | N/A | N/A | N/A | N/A | 42(1067) | N/A |
Double | 11.5(292) | 8(203) | 19.5(495) | 27.5(699) | 10(254) | 18(457) | N/A | N/A | N/A | N/A | 42(1067) | N/A |
REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL: Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL103 HT listed
Double | N/A | 4(102) | 19.5(495) | 25.5(658) | 10(254) | 16(406) | N/A | N/A | N/A | N/A | 30(762) ceiling | N/A |
Double | N/A | 4(102) | 19.5(495) | 27.5(699) | 10(254) | 18(457) | N/A | N/A | N/A | N/A | 30(762) ceiling | N/A |
|
|
|
|
| USA or Canada |
|
*NFPA MINIMUM CLEARANCE - NOT TESTED
Page 6 |