Wall Control - WSK300
Control Specifications
Auxiliary Features
The !58 button will operate the following 3 auxiliary features:
A1 = FAN (always room heating)
A2 = SWITCHES 110VAC, HI/MED/LOW
A3 = SWITCHES 110VAC, ON/OFF
First press the !58 button multiple times to scroll through to the desired Auxiliary feature (A1, A2, or A3).
If desired Auxiliary selected is A1 or A2
use the UP or DOWN arrow to step through the following 4 levels:
OFF
L1 = Low
L2 = Medium
L3 = High
Wall Control
Press UP or DOWN arrow buttons to determine desired setting
AUXILIARY function level indicator
0),/4 | !58 | AUXILIARY button |
Function - AUXILIARY features
&!.
•Upon entering the OFF mode, all auxiliaries will be turned off with the fireplace with the exception of A1 after leaving THERMOSTAT mode. This mode activates a FAN
•A1 may be operated during the ON mode as desired. During the THERMOSTAT mode A1 (FAN) will be adjusted automatically (between OFF, L1 and L2) based on the desired room temperature setting. It will also perform a
•Auxiliaries A2 and A3 may be adjusted in any of the
3 modes. When the ON or THERMOSTAT mode is active these settings will be saved to memory and set back to the desired levels when ON or THERMOSTAT mode is activated again.