Wall Control - WSK300

Control Specifications

Auxiliary Features

The !58 button will operate the following 3 auxiliary features:

A1 = FAN (always room heating)

A2 = SWITCHES 110VAC, HI/MED/LOW

A3 = SWITCHES 110VAC, ON/OFF

First press the !58 button multiple times to scroll through to the desired Auxiliary feature (A1, A2, or A3).

If desired Auxiliary selected is A1 or A2

use the UP or DOWN arrow to step through the following 4 levels:

OFF

L1 = Low

L2 = Medium

L3 = High

Wall Control

4(%2-/34!4 /&& /.

-/$%

Press UP or DOWN arrow buttons to determine desired setting

AUXILIARY function level indicator

0),/4

!58

4)-%2

AUXILIARY button

Function - AUXILIARY features

&!.

Upon entering the OFF mode, all auxiliaries will be turned off with the fireplace with the exception of A1 after leaving THERMOSTAT mode. This mode activates a FAN cool-down feature that will continue to operate the fan until all remaining heat has been blown into the room.Auxiliary A1 (FAN) may not be operated in the OFF mode, as this auxiliary is always a room-heating fan.

A1 may be operated during the ON mode as desired. During the THERMOSTAT mode A1 (FAN) will be adjusted automatically (between OFF, L1 and L2) based on the desired room temperature setting. It will also perform a warm-up when entering THERMOSTAT mode, and cool-down when the flame is no longer necessary to heat the room. This allows energy to be conserved as the fan will only operate when the fireplace is warm.

Auxiliaries A2 and A3 may be adjusted in any of the

3 modes. When the ON or THERMOSTAT mode is active these settings will be saved to memory and set back to the desired levels when ON or THERMOSTAT mode is activated again.

13

Page 13
Image 13