16

Condition (at time of power failure) Result

The wall switch is in ON mode with the main ame on and it has
battery backup The replace will stay on and the main burner will turn to HIGH,
the FOL* (Flame on a Log) will also have ame. The display
lights in the wall switch will be off and the replace can be turned
on and off by pressing the mode button.
If the main ame is on when the power is restored to the system,
it will return to the ON mode and the display lights in the wall
switch will come back on.
If the main ame is off when the power is restored to the system,
it will go to OFF mode and the display lights in the wall switch will
come back on.
*Not all units using this system have a FOL (Flame on a Log)
feature.
The wall switch is in OFF mode with the main ame off and it has
battery backup. The replace main burner will stay off. The display lights in the
wall switch will be off and the replace can be turned on and off
by pressing the MODE button.
If the main ame is on when the power is restored to the system,
it will return to the ON mode and the display lights in the wall
switch will come back on.
If the main ame is off when the power is restored to the system,
it will go to OFF mode and the display lights in the wall switch will
come back on.
TROUBLESHOOTING (continued)

The operating characteristics of your replace may vary during a power failure or power outage. the options listed below

will help determine the current state of your system.

SERVICE PARTS

DESCRIPTION PART NUMBER
Wall Switch Wire 2095-550
Solenoid, Hi/Lo Flame 2101-029
Wall Control Assembly 2106-072
Control Box Assembly
(includes 1 cord assembly and 1 cable assembly) 2106-025