Heat & Glo LifeStyle 36DV manual B. Installing Vent Components, Venting Out the Top Vent

Models: 36DV

1 26
Download 26 pages 27.68 Kb
Page 16
Image 16
B. Installing Vent Components

B. Installing Vent Components

Venting Out the Top Vent

The glass must be taken off again for positioning the logs when the unit is finally installed in place and finished around it. Re-install the glass door. Attach vent system to the top starting collars.

1.Attach the First Vent Component to the Starting Collars

To attach the first vent component to the starting collars of the fireplace:

Refer to Cinch Pipe (DVP) and Termination Cap installation instructions.

2. Continue Adding Vent Components

Continue adding vent components snap-locking, locking

 

each succeeding component into place.

Ensure that each succeeding vent component is secure-

 

ly fitted and locked into the preceding component in the

 

vent system. Securing pipe sections with a maximum of

NOTE: There must be NO INSULATION or other combustibles inside the framed firestop opening.

10"

INTERIOR

WALL SHIELD

12"

Figure 14. 10" x 12" Hole and Vent Pipe

two screws is recommended.

• 90° elbows may be installed and rotated to any point

around the preceding component’s vertical axis. If an el-

bow does not end up in a locked position with the pre-

ceding component, attach with a minimum of two (2)

sheet metal screws.

3. Install Support Brackets

Refer to Cinch Pipe and Termination Cap installation instructions.

4. Install Firestops

For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes.

HEAT SHIELD

INTERIOR

FIRESTOP

TRIM HEAT SHIELD IF TOO LONG, ADD TO SHIELD IF TOO SHORT

EXTERIOR

FIRESTOP

NOTE: Model DVP-TRAP does not need an exterior firestop on an exterior combustible wall.

To install firestops for horizontal runs that pass through either interior or exterior walls:

Cut a 10-inch by 12-inch (254mm X 305mm) hole through the wall.

NOTE: The center of the hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe.

Position the firestops on both sides of the hole previ- ously cut and secure the firestops with nails or screws.

The heat shields of the firestops MUST BE placed to- wards the top of the hole.

Continue the vent run through the firestops.

Figure 15. Heat Shield, Interior & Exterior Firestops

16

Page 16
Image 16
Heat & Glo LifeStyle 36DV manual B. Installing Vent Components, Venting Out the Top Vent, Continue Adding Vent Components