2. Top Vent - Vertical Termination

2. Top Vent - Vertical Termination

V1 = 40 ft. Max. (12.4 m)

V1 = 3 ft. Min. (914 mm)

Note: If installing a vertical vent/ termination off the top of the appli- ance, the optional vertical termina- tion baffle should be used.

No Elbow

Figure 5.6

Flue Restrictor Instructions

1.Remove Exhaust Shield using a 1/4 inch nut driver by removing the four screws securing it in place (see Figure 5.7).

E X H A U S T

S H IE L D

F L U E

R E S T R IC T O R

Figure 5.7

2.Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 5.8).

B R E A K

H E R E

Figure 5.8 Flue Restrictor

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08