Heat & Glo LifeStyle 6000G-LP D. Standing Pilot Ignition System Wiring, Shock hazard

Models: 6000G-IPILP 6000G-IPI 6000G 6000G-LP

1 71
Download 71 pages 31.89 Kb
Page 39
Image 39
D. Standing Pilot Ignition System Wiring

PLUG-IN

3V TRANSFORMER

ON/OFF

WALL SWITCH

IGNITION MODULE (3V)

VALVE

LOW VOLTAGE

 

SEE NOTE 1

NEUTRAL

GROUND REMOTE

 

CONTROL HOT

BLACK WIRE CAN BE

PLUGGED INTO ANY

OF #1 - #5 LOCATIONS

ON THE HOT SIDE

WHITE WIRE CAN BE

PLUGGED INTO ANY

OF#1 - #5 LOCATIONS

ON THE NEUTRAL SIDE

TRANSFORMER

3 VAC

PLUG-IN

IGNITION MODULE 3 VAC

INTERMITTENT

PILOT IGNITOR

 

 

ORG

 

 

WHT

 

 

GROUND TO

 

 

FIREPLACE

 

 

CHASSIS*

BLK

 

ORG

 

 

RED

BRN

GRN

BRN

 

THERMOSTAT

 

WIRE

VALVE

ASSEMBLY

 

REMOTE

JUMPER WIRE

Figure 10.2 Intellifire Pilot Ignition (IPI) Wiring Diagram

*Note: Appliance will not operate unless properly grounded.

D. Standing Pilot Ignition System Wiring

This standing pilot ignition system wiring does not require a 110 VAC supply to operate.

It is recommended that a 110 VAC junction box be installed for use with a fan or remote control. (See Figure 10.4 for junction box wiring).

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Shock hazard. WARNING

Shock hazard.

Replace damaged wire with type 105º C rated wire.

Wire must have high temperature insulation.

S TA N D IN G

 

 

 

P IL O T

 

 

 

 

B R N

 

 

 

R E D

 

 

VA LV E

O N /O F F P IG G Y B A C K

T H E R M O S TAT

 

W H T

W IR E A S S E M B LY

 

W IR E

 

 

 

R E D

 

 

 

Figure 10.3 Standing Pilot Ignition Wiring Diagram

 

 

 

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08

39

Page 39
Image 39
Heat & Glo LifeStyle 6000G-LP, 6000G-IPILP owner manual D. Standing Pilot Ignition System Wiring, Shock hazard