13 Maintaining and Servicing the Appliance

13 Maintaining and Servicing the Appliance

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance check-up at the beginning of each heating season.

Risk of injury or property damage WARNING

Risk of injury or property damage

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After Servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

Before servicing: WARNING

Fire Risk

Explosion Risk

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

A.Annual Maintenance

To ensure that your gas appliance operates in a safe and effi cient manner, it needs to be inspected at least on an an- nual basis by a qualifi ed fi eld service person. Like any gas appliance, This gas appliance must be tuned up to ensure optimum performance.

Note: After extended periods of burning, fi lm may build up on the fl ame sensor. The fl ame sensor should be cleaned annually with emery cloth to remove this build up.

B. Cleaning the Burner and Control Compartment

Keep the burner and control compartment clean by brushing and vacuuming at least once a year. Always turn the wall (or dashboard switch) and the gas valve off before cleaning.

C. HRV200PLUS

Please refer to the HRV200PLUS manual for additional maintenance requirements for the ventilation portion of the 6100PLUS.

After Servicing: WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts.

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of fi rebox.

Burner ignition and operation.

Burner air shutter adjustment.

Gas connections and fi ttings.

Obstructions of termination cap.

Clean:

Glass.

Air passageways, grilles, control compartment.

Burner, burner ports.

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

D.Ember Bed Bulb Replacement

Remove two screws from dash plate holding each bulb bracket.

Pull socket down and forward to access bulb, replace the bulb and return to installed position. See Figure 13.1.

Figure 13.1 Bulb Replacement