Heat & Glo LifeStyle 7000XLT manual The Gas Control System, Proper Positioning, Leveling, and

Models: 7000XLT

1 31
Download 31 pages 20.62 Kb
Page 25
Image 25
Figure 23. Proper Positioning, Leveling, and

Step 4. Positioning, Leveling, and Securing the Fireplace

The diagram below shows how to properly position, level, and secure the fireplace.

Figure 23. Proper Positioning, Leveling, and

Securing of a Fireplace

Place the fireplace into position.

Level the fireplace from side to side and from front to back.

Shim the fireplace with non-combustible material, such as sheet metal, as necessary.

Secure the fireplace to the framing by nailing or screwing.

Step 5. The Gas Control System

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

The type of gas control system used with this model is Stand- ing Pilot Ignition.

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

!WARNING: 110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

 

STANDING PILOT

Figure 24.

Gas Control System

25

Page 25
Image 25
Heat & Glo LifeStyle 7000XLT manual The Gas Control System, Proper Positioning, Leveling, and, Securing of a Fireplace