Heat & Glo LifeStyle BAY-38HV manual The Gas Control Systems, Proper Positioning, Leveling, and

Models: BAY-38HV

1 32
Download 32 pages 13.37 Kb
Page 25
Image 25
Figure 26. Proper Positioning, Leveling, and

Step 4. Positioning, Leveling, and Securing the Fireplace

The diagram below shows how to properly position, level, and secure the fireplace.

Figure 26. Proper Positioning, Leveling, and

Securing of a Fireplace

Place the fireplace into position.

Level the fireplace from side to side and from front to back.

Shim the fireplace with non-combustible material, such as sheet metal, as necessary.

Secure the fireplace to the framing using nails or screws through the nailing tabs.

Step 5. The Gas Control Systems

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Two types of gas control systems are used with these models: Standing Pilot Ignition and Direct Spark Ignition (DSI).

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

!WARNING: 110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

 

STANDING PILOT

 

DSI

 

3/8”

 

(10mm)

Figure 27.

Gas Control Systems

Direct Spark Ignition (DSI) System

This system includes a 120 VAC control valve, electronic module, and spark ignitor/flame sensor.

WARNING: CONTINUOUS 110-120 VAC

!SERVICE MUST BE WIRED DIRECTLY TO THE FIREPLACE JUNCTION BOX IN A DSI SYSTEM.

WARNING: DIRECT VENT PROPANE MODELS

!WITH DSI CONTROL SYSTEMS CANNOT BE USED IN CANADA.