Step 4. Positioning, Leveling, and Securing the Fireplace
The diagram below shows how to properly position, level, and secure the fireplace.
Figure 26. Proper Positioning, Leveling, and |
Securing of a Fireplace |
•Place the fireplace into position.
•Level the fireplace from side to side and from front to back.
•Shim the fireplace with
•Secure the fireplace to the framing using nails or screws through the nailing tabs.
Step 5. The Gas Control Systems
!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Two types of gas control systems are used with these models: Standing Pilot Ignition and Direct Spark Ignition (DSI).
Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.
!WARNING:
| STANDING PILOT |
| DSI |
| 3/8” |
| (10mm) |
Figure 27. | Gas Control Systems |
Direct Spark Ignition (DSI) System
This system includes a 120 VAC control valve, electronic module, and spark ignitor/flame sensor.
WARNING: CONTINUOUS 110-120 VAC
!SERVICE MUST BE WIRED DIRECTLY TO THE FIREPLACE JUNCTION BOX IN A DSI SYSTEM.
WARNING: DIRECT VENT PROPANE MODELS
!WITH DSI CONTROL SYSTEMS CANNOT BE USED IN CANADA.
25