Heat & Glo LifeStyle Montana-36 TV342, TR342/TR344, TR442/TR444, TR11/TR11T, Shroud, Top Vent

Models: Montana-42 Montana-36

1 44
Download 44 pages 8.07 Kb
Page 37
Image 37
TV342

Woodburning Termination Cap

 

 

 

TV342

 

 

 

 

 

 

TR342/TR344*

 

 

TV11/TV11T

 

TS345/T445

TR342/TR344

TR442/TR444*

 

 

TR11/TR11T*

Shroud

(Top Vent)

TR442/TR444

(* with TR-TVK installed)

TR11/TR11T

 

(* with TR-TVK installed)

 

 

OPEN TOP with solid sides and 3 in. (76 mm) opening at the bottom

 

 

 

 

 

 

 

 

Mnimum Base

23 in. x 23 in.

28 x 28 in.

26 x 26 in.

32 x 32 in.

 

26 x 26 in.

(711 x 711 mm)

(813 x 813 mm)

 

Dimensions

(584 x 584 mm)

(660 x 660 mm)

 

(660 x 660 mm)

with Radiation Shield

with Radiation Shield

 

 

 

 

 

 

Minimum Top

20 x 20 in.

25 x 25 in.

23 x 23 in.

29 x 29 in.

 

23 x 23 in.

Dimensions

(508 x 508 mm)

(635 x 635 mm)

(584 x 584 mm)

(737 x 737 mm)

 

(584 x 584 mm)

 

 

 

 

 

 

 

MAILBOX STYLE with open ends and 3 in. (76 mm) opening at the bottom of the sides.

 

 

 

 

 

28 x 30 in.

Minimum Base

 

26.5 x 28 in.

28 x 30 in.

34 x 34 in.

(711 x 762 mm)

N/A

(673 x 711 mm)

(864 x 864 mm)

with Radiation Shield or

Dimensions

(711 x 762 mm)

 

with Radiation Shield

with Radiation Shield

34 x 34 in.

 

 

 

 

 

 

 

 

(864 x 864 mm)

 

 

 

 

 

 

Minimum Height

N/A

28 1/4 in.

27 1/2 in.

28 1/4 in.

27 1/2 in.

(718 mm)

(699 mm)

(718 mm)

(699 mm)

 

 

 

 

 

 

 

 

ROOFED STYLE with 12 x 22 in. (264 sq. in.) (305 x 559 mm) opening on each side and 3 in. (76 mm) space between the

radiation shield and chase top.

Minimum Base

 

27 x 27 in.

27 x 27 in.

34 x 34 in.

34 x 34 in.

N/A

(686 x 686 mm)

(686 x 686 mm)

(864 x 864 mm)

(864 x 864 mm)

Dimensions

 

with Radiation Shield

with Radiation Shield

with Radiation Shield

with Radiation Shield

 

 

Minimum Height

N/A

23 in.

23 in.

23 in.

23 in.

(584 mm)

(584 mm)

(584 mm)

(584 mm)

 

 

 

 

 

 

 

 

Minimum Height is measured from the bottom of the termination cap:

Minimum height is established with the bottom of the termination cap 7 in. (178 mm) above the chase top. Minimum height must increase accordingly for any height above 7 in. (178 mm).

All dimensions are INSIDE dimensions.

Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06