E. Chimney Requirements

E. Chimney Requirements

When planning your fireplace location, the chimney construc- tion and necessary clearances must be considered. The fire- place system and chimney components have been tested to provide flexibility in construction. The following figures are the minimum distances from the base of the fireplace.

Minimum overall straight height is 6 ft 4 in. if the fire- place is freestanding a minimum of 10 ft from a combus- tible structure. See Figure 3.2.

 

ft

m

• Minimum overall straight height

14

4.27

• Minimum height with offset/return

16

4.88

• Maximum height

90

27.43

• Maximum chimney length between an offset

20

6.1

and return

 

 

• Maximum distance between chimney

35

10.67

stabilizers

 

 

• Double offset/return minimum height

24

7.32

• Maximum unsupported chimney length

6

1.83

between the offset and return

 

 

• Maximum unsupported chimney height above

35

10.67

the fireplace

 

 

• Minimum overall straight height if fireplace is

6.33

1.93

freestanding

 

 

Note: A maximum of two pairs of offsets and returns may be used.

12

Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06