Heat & Glo LifeStyle SLR-B (COSMO) Top Vent Vertical Termination Venting with 4 elbows

Models: SLR-B (COSMO)

1 68
Download 68 pages 13.27 Kb
Page 32
Image 32

Top Vent - Vertical Termination

Venting with 4 elbows

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using

ex vent except when using the simple up and out installation (see Figure 5.3).

V1 MIN.

 

H1 MAX.

V2 MIN.

H2 MAX.

V3 MIN.

1-1/2 ft.

457 mm

 

4 ft.

1.2 m

4 ft.

1.2 m

4 ft.

1.2 m

3-1/2 ft.

1.0 m

 

 

 

 

 

 

 

 

 

 

 

 

 

V1 + V2 + V3 + H1 + H2 Maximum= 40 ft. (12.2 m)

 

 

V3

H2

H1

V1

V2

Figure 7.13

32