Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H.Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above fi nished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfi ed:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fi tter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualifi ed licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent fl oor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certifi ed.

Signage

A metal or plastic identifi cation plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) in. in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the fl ue gases, but identifies “special venting systems”, the following requirements shall be satisfi ed by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment in- stallation instructions; and

The “special venting systems” shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

8

Heat & Glo • SLR-B2195-900 Rev. P • 12/11

Page 8
Image 8
Heat & Glo LifeStyle SLR-B (COSMO) owner manual Requirements for the Commonwealth of Massachusetts

SLR-B (COSMO) specifications

The Heat & Glo LifeStyle SLR-B (COSMO) is a revolutionary gas fireplace that embodies modern design while prioritizing efficiency and sophistication. Known for its sleek lines and contemporary aesthetic, the SLR-B blends seamlessly into various home décors, making it a popular choice among homeowners who value both style and functionality.

One of the standout features of the SLR-B is its panoramic viewing glass. The expansive front glass panel offers an unobstructed view of the flames, creating a stunning focal point in any room. This design not only enhances the ambiance but also allows for a more radiant heat output, efficiently warming the space while inviting a captivating visual element into the home.

The SLR-B utilizes advanced burner technology, which ensures a clean and efficient burn, producing realistic flames that mimic the look of natural wood fires. The unique firebox design enhances combustion efficiency, maximizing heat output while minimizing emissions. This aligns with modern environmental standards and provides homeowners with peace of mind regarding their energy consumption.

Compatibility with home automation systems is another attractive aspect of the SLR-B. With options for remote control and smart technology integration, users can control the fireplace settings from anywhere in the home, providing convenience and comfort. The inclusion of adjustable flame height adds personalization, allowing users to create the ideal atmosphere based on their preferences.

Safety is paramount in the design of the SLR-B. The fireplace comes with a sealed combustion system, which prevents drafts and enhances indoor air quality by minimizing the infiltration of outside air. Additionally, an intuitive control system informs users of the fireplace's status and ensures the right operation settings, contributing to a safer user experience.

With customizable media options, including various decorative stones or logs, the SLR-B allows for personal expression, harmonizing the design with individual tastes. This versatility makes it suitable for diverse spaces, from modern apartments to traditional homes.

In summary, the Heat & Glo LifeStyle SLR-B (COSMO) combines cutting-edge technology with aesthetic appeal. Its panoramic design, eco-friendly combustion, smart technology integration, safety features, and customizable options make it a top choice for homeowners seeking a sophisticated heating solution that enhances their living spaces.