1 SELECT THE BEST LOCATION

Installation Instructions

Read these instructions completely and carefully; then follow step by step.

1 SELECT THE BEST LOCATION

A INDOOR UNIT

Do not allow any heat or steam near the unit .

Select a location where there are no obstacles

in front of the unit .

Make sure that condensate drainage can be

conveniently routed away.

Do not install near a doorway.

Ensure that the space around the left and right

BOUTDOOR UNIT

If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.

Ensure that the space around the back and sides is more than 12. The front of the unit should have more than 79of space.

of the unit is more than 6. The unit should be

installed as high on the wall as possible, allowing

a minimum of 6from ceiling.

Use a stud finder to locate studs for mounting and

to prevent unnecessary damage to the wall.

Install on studs and in a location from which

the condensation water can be drained out

conveniently and that permits easy connection

with the outdoor unit .

More than 12”

More than 79” A INDOOR UNITBOUTDOOR UNIT

Manual background More than 12

The platform must

support a minimum of 200 lbs. See Installation Dimensions for mounting

hole spacing.

Do not cover the inlet and outlet so that the

outflow air can reach all parts of the room.

Install in a location that is strong enough to

withstand the full weight and vibration of the unit .

Be sure that the installation conforms to the

installation dimension diagram.

Leave enough space to allow access for routine

maintenance. The height of the installed location

should be 79or more away from the floor.

Install in a location that is 3 ft . or more away from

other electrical appliances, such as televisions and

audio devices.

Select a location that gives you easy access to

remove and clean the filter.

 

More than 6”

More

More

than 6”

than 6”

More than 79”

Install in a location that is strong enough to permit safe installation and to withstand the full weight and vibration of the unit .

Construct and anchor a strong and level mounting base or pad for the outdoor unit .

Anchor the outdoor unit through its four mounts, using bolts.

Select a location from which noise and outflow air emitted by the unit will not inconvenience neighbors.

In humid locations, the unit may sweat and condensation (water) may drip from it . Take this into consideration when choosing the location.

Select a location that has sufficient ventilation.

Do not cover the inlet and outlet .

Install unit away from flammable gas or corrosive gas leaks.

Be sure the installation conforms to the installation dimension diagram.

Rooftop Installations:

If the outdoor unit is installed on a roof structure, be sure to level the unit . Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.

10

Page 10
Image 10