13TEST OPERATION AND CHECK AFTER INSTALLATION

Installation Instructions

13TEST OPERATION AND CHECK AFTER INSTALLATION

Test operation

1.Before test operation

Do not switch on power before installation is finished completely.

Electrical wiring must be connected correctly and securely.

Shut-off valves of the connection tubes should be opened.

All impurities such as scraps and particulates must be cleared from the unit .

2.Test operation method

Switch on power and press the ON/OFF pad on the remote control to turn on the air conditioner.

Press the MODE pad and check the operation conditions of each of the modes.

10,000 and 14,000 BTU models only:

If the remote control is lost, the emergency run operation can be performed with a ballpoint pen or similar object .

a. When the unit is off, set the handling switch to the AUTO mode. The unit will then automatically run in the mode selected by the microcomputer system according to the surrounding temperature. If you want to turn the unit off, press the handling switch again.

b. When the unit is on, set the handling switch to the STOP mode to turn off the unit .

20,000 BTU models only:

If the remote control is lost, open the front access panel and perform the following:

a.Set the handling switch to the AUTO position to operate in the AUTO mode. Once there is a remote control signal, the unit will again be controlled by that signal.

b.Set the handling switch to the STOP position to turn off the unit .

10,000 and 14,000 BTU Models

Test operation1.Before test operation2.Test operation method10,000 and 14,000 BTU models only:20,000 BTU models only: Handling switch

20,000 BTU Models

Handling switch

Installation Checklist

Has the unit been securely installed? If not, the unit may fall, shake or make noises.

Has the refrigerant leak test been performed? Leakage may cause insufficient cooling capacity.

Does the unit drain well? Poor drainage can cause condensation and dripping.

Is the voltage correct according to the nameplate? Incorrect voltage may cause electrical malfunction. Diagnostic information is available for this unit. Contact your service technician.

Is the unit properly grounded? A nonsecure ground connection can cause damage.

Are the air inlet and outlet completely free of cover? Covering the air inlet or outlet may cause insufficient cooling capacity.

Have the length of the connection tubing and refrigerant capacity been recorded? It is important to know these things for future reference.