GE AE0CD14DM 7INSTALL THE INDOOR UNIT cont, Installation Instructions 2 INSTALLATION cont

Models: AE1RD10AM AE0RD20DM AE0RD10AM AE1CD14DM AE1CD10AM AE0CD20DM AE0RD14DM AE1RD14DM AE1RD20DM AE1CD20DM AE0CD14DM AE0CD10AM

1 56
Download 56 pages 24.81 Kb
Page 13
Image 13
7INSTALL THE INDOOR UNIT

Installation Instructions

2 INSTALLATION (cont.)

7INSTALL THE INDOOR UNIT

Route the tubes and wiring from the right side of the indoor unit . Cut off the tailings from the chassis as necessary.

1.Cut off tailings 1 when routing the wiring only.

2.Cut off tailings 1 and 2 (or tailings 1, 2 and 3) when routing both the wiring and tubing. 1 and 2 below are the recommended tubing.

1 Right tube

2 Right rear tube

7INSTALL THE INDOOR UNIT (cont.)

Wrap the tubes and wiring and pull them through the cut-off-tailings hole.

Wrapping tape

 

Connection tubes

 

Power

Control cord (for

cooling/heating

connection cord

type only)

 

Drainage hose

Hang the mounting slots of the indoor unit on the upper tabs of the mounting plate and make sure it is firm enough.

Tailings 3 Tailings 2

Tailings 1

The height of the installed location should be 79or more from the floor.

13

Page 13
Image 13
GE AE0CD14DM, AE0CD10AM, AE1CD20DM 7INSTALL THE INDOOR UNIT cont, Installation Instructions 2 INSTALLATION cont