Installation Instructions

Installation Instructions

Mini Split-System Air Conditioners

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT Save these instructions for local inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Skill level – A licensed, certified (to handle refrigerant- R410A, recovery, etc.) technician and a qualified electrician are required for installation of this split

air conditioning system.

Completion time – Approximately 212 hours

Two people are required to install this unit due to the weight of the product .

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

For personal safety, this system must be properly grounded.

Protective devices (fuses or circuit breakers) acceptable for installation are specified on the nameplate of each unit .

Servicing and installation of the refrigerant system must be performed only by a licensed, HVAC-certified technician.

Make sure to avoid wiring or plumbing inside the wall when installing.

For any service which requires entry into the refrigerant sealed system, Federal regulations require the work be performed by a technician having a Class II or Universal certification.

Mini Split-System Air ConditionersELECTRICAL REQUIREMENTS

Be certain all wiring complies with local building codes and NEC and that the supply voltage for this system is correct. The system supply voltage is connected to the outdoor unit only.

Check the rating nameplate on the side panel of outdoor unit for required circuit protection rating and required supply voltage.

Use UL-approved electrical branch circuit disconnect for providing supply voltage to split system indoor and outdoor units. Locate disconnect within sight and readily accessible per NEC and local codes.

All wiring should be rated appropriate for the current value listed on the rating plate.

Be certain there is an uninterrupted, unbroken electrical ground connection.

Wiring should be encased in liquid-tight tubing with connections sealed with liquid-tight connectors.

BEFORE YOU BEGINCAUTION:

Do not use an extension cord with this system.

Aluminum building wiring may present special problems—consult a qualified electrician.

When the unit is in the STOP position, there is still voltage to the electrical controls.

Disconnect the power to the system before servicing by removing the branch circuit fuses or turning the circuit breakers off at the panel.

DO NOT use equipment certified for R22 refrigerant only.

8

Page 8
Image 8
GE AE1CD14DM Installation Instructions, Mini Split-SystemAir Conditioners, Before You Begin, Electrical Requirements