1.5.1INSTALLING THE ELECTRICAL SERVICE TO THE JUNCTION BOX

WARNING: TURN ELECTRICAL POWER OFF AT THE CIRCUIT BREAKER BEFORE BEGINNING IN- STALLATION.

1.Remove the electrical cover plate from the lower side of the heater. Remove the knockout from the plate and attach the Romex clamp (screws to the out- side.)

2.Feed the electrical services wires through the Romex clamp and secure the wire to the clamp.

3.Using the wire connector provided inside the junc- tion box, attach the neutral service wire to the blue wire, the hot service wire to the black wire, and the service ground wire to the ground screw stud of the junction box. See Figure 22 for wire connection de- tail and Figure 21 for a complete wiring diagram.

4.Re-attach the cover plate to the outside of the heater.

!WARNING: DO NOT CONNECT 220 VAC TO THE GAS CONTROL VALVE OR CON- TROL WIRING SYSTEM OF THIS MODEL.

FIGURE 22

1.6 MANTEL CLEARANCES

Clearance to a mantelpiece is 6-inches (152mm). See Figure 23.

IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 150° C. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON- COMBUSTIBLE MATERIAL (USING 150° C.

MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND. SEE FIGURE 24.

279

 

 

254

 

 

229

 

 

203

 

 

178

 

 

152

 

279

 

229

 

 

203

254

 

 

 

152

 

 

178

 

 

TOP FRONT EDGE

 

 

OF FIREPLACE

 

 

NOTE: ALL DIMENSIONS ARE

SHOWN IN MILLIMETERS.

 

FIGURE 23

HIGH TEMP

(300oF. 150oC. MIN.)

SEAL JOINT

FINISHED

WALL

STUD

2 X 4

HEADER

TOP STANDOFF

HIGH TEMP

(300oF. 150oC. MIN.)

SEAL JOINT

FIGURE 24

1.7 LOG INSTALLATION

Carefully remove the log packages from the heater and the tags from their packages. Handle logs gently. Place the logs in the heater by following the steps shown in Figure 25. Replace the glass door and dress guard previously removed prior to lighting the unit. Be certain the gas logs are properly positioned.

19

Page 19
Image 19
Heat & Glo LifeStyle ST-38HV-AU Installing the Electrical Service to the Junction BOX, Mantel Clearances, LOG Installation