| COMBUSTIBLE | HOUSEWRAP |
| SHEATHING |
|
| REQUIRED |
|
| FLASHING | |
| (SUPPLIED WITH | SHEATHING |
|
| |
|
| BRICK |
|
| LEDGE |
|
| 12 IN. |
| REQUIRED | NON- |
| HOOD | COMBUSTIBLE |
| (SUPPLIED WITH | FACING |
|
| |
|
| 6 IN. |
|
| MAX. |
|
| THERE MUST BE NO GAP |
|
| BETWEEN BRICK LEDGE, |
|
| FACING MATERIAL AND |
| HOUSE | APPLIANCE FRONT. |
|
| |
| WRAP |
|
| 6 INCH MAXIMUM | |
| PROJECTION FROM | |
| SHEATHING | FACE OF APPLIANCE |
| 12 IN. |
|
Í | Figure 8.3 Exterior View |
|
|
|
Outside Facing Material
Î WARNING
Fire Risk.
Water Intrusion Risk.
•
•May install
WARNING
Fire Risk.
Finish all edges and fronts to clearances and specifications listed in manual.
•Black metal columns may be covered with non- combustible material only.
•Do NOT overlap combustible materials onto appliance front.
•Install combustible materials up to specified clear- ances on top front and side edges.
•Seal joints between the finished wall and appliance top and sides using only a 300oF minimum sealant.
Heat & Glo LifeStyle Collection • | 19 |