8 Finishing

8 Finishing

A. Mantel Projections

Figure 8.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance.

Interior

NON-COMBUSTIBLE BOARD

View

(SUPPLIED ON APPLIANCE)

 

 

 

12

 

 

10

11

 

 

 

 

 

9

 

 

 

8

 

 

 

7

13-5/8

 

 

6

12-5/8

 

 

11-5/8

 

 

10-5/8

 

 

 

9-5/8

 

 

 

8-5/8

 

 

HOOD

7-5/8

 

 

 

Note: Measurements

 

 

are in inches.

 

Figure 8.1

Indoor Clearances to Mantels or other

 

Combustibles above Appliance

 

TOP VIEW

MEASURED

FROM CORNER

A. Mantel Projections ½ IN.

FIREPLACE

HOOD

Figure 8.2 Clearances to Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening.)

B. Facing Material

B. Facing MaterialInside Facing MaterialWARNING

Fire Risk.

Do NOT obstruct air inlet or outlet grilles.

Do NOT modify grilles.

Modifying or covering grilles could cause

temperature rise and fire hazard.

Finishing materials must not interfere with:

Air flow through grilles or louvers.

Operation of louvers or doors.

Access for service.

Inside Facing Material

May install combustible materials up to specified clearances on top, front and sides of appliance.

Seal joints between finished wall and appliance top and sides with 3000 F (1400C) minimum sealant.

Leave space so bottom grille can be lowered for trim door removal.

18