NOTE: The thermostat must be configured for programmable mode by installer to access the Programmed Demand Reduction settings.
5.6.5.5.1PROGRAMMED DEMAND REDUCTION MODE
Through Programmed Demand Reduction Mode, you can set the unit’s limited operation during the Programmed Demand Reduction schedule.
Adjust the Programmed Demand Reduction Mode settings using the up/down arrow buttons. Press the center button to save changes.
DEMAND REDUCTION
OPTION FOR
PROGRAM OPERATION
NO DEMAND REDUCTION
NO AUXILIARY HEAT
NO 2ND STAGE COMP
SELECT OPTION
PREVIOUS SAVE
•No Demand Reduction (default): During the scheduled Programmed Demand Reduction time (section 5.6.5.5.4), the system operates normally based on the setpoints.
•No Auxiliary Heat: During the scheduled Programmed Demand Reduction time (section 5.6.5.5.4), auxiliary heat will not be activated, regardless of the heating demand.
•No 2nd Stage Compressor: During the scheduled Programmed Demand Reduction time (section 5.6.5.5.4), the compressor is limited to only part load (1st stage) operation and auxiliary heat is turned off, regardless of system demand.
NOTE 1: The thermostat must be configured for auxiliary heat by installer to access the Demand Reduction NO AUXILIARY HEAT option.
NOTE 2: The thermostat must be configured for Multistage by installer to access the Demand Reduction NO 2nd STAGE COMP option.
5.6.5.5.2Whole House Dehumidification -
PROGRAMMED DEMAND REDUCTION This option allows for the customization of Whole House Dehumidification. (Dehumidification, optional) operation during the Programmed Demand Reduction schedule.
PROGRAMMED DEMAND
REDUCTION OPERATION
FOR CLIMADRY
WHEN DEMAND REDUCTION
IS ACTIVE
SUSPEND CLIMADRY
ALLOW CLIMADRY
SELECT OPTION
PREVIOUS SAVE
Adjust the Programmed Demand Reduction Whole House Dehumidification settings using the up/down arrow buttons. Press the center button to save changes.
•Suspend Whole House Dehumidification (default): During the scheduled Programmed Demand Reduction
time (section 5.6.5.5.4), Whole House Dehumidification is turned off, regardless of the dehumidification demand.
•Allow Whole House Dehumidification: During the scheduled Programmed Demand Reduction time (section 5.6.5.5.4), Whole House Dehumidification will operate normally.
NOTE: The thermostat must be configured for humidity control by installer and the DXM2 must be configured for Whole House Dehumidification operation to access Demand Reduction Whole House Dehumidification settings.
5.6.5.5.3FAN - PROGRAMMED DEMAND REDUCTION
This option allows for the customization of fan settings during the Programmed Demand Reduction schedule.
PROGRAMMED DEMAND
REDUCTION FAN
OPERATION
WHEN DEMAND REDUCTION
IS ACTIVE
AUTO FAN ONLY
ALLOW CONSTANT FAN
SELECT OPTION
PREVIOUS SAVE
Adjust the Programmed Demand Reduction Fan settings using the up/down arrow buttons. Press the center button to save changes.
11