7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT

Heat Controller, Inc.

 

 

 

Heat Setpoint (default current Heat Setpoint): valid range: 55°F to Maximum Heating Setpoint Limit (section 5.6.8)

Cool Setpoint (default current Cool Setpoint): valid range: Minimum Cooling Setpoint Limit (section 5.6.8) to 95°F

NOTE: The thermostat forces a 2°F “dead-band” between the Heating and Cooling setpoints. While adjusting the Heating setpoint, the Cooling setpoint may be automatically increased to enforce a 2°F “dead-band”. Likewise, while adjusting the Cooling setpoint, the Heating setpoint may be automatically reduced to enforce a 2°F “dead-band”.

5.2.1.2 HOLD TIME

Set the Vacation Hold time period.

Adjust the date using the up/down arrow buttons. Press the center button to save changes.

Date (default current Date): in 1 day increments

Time (default current Time): in 10 minute increments

5.2.2 PERMANENT

The thermostat can be programmed to hold the temperature and override the program schedule permanently.

The Permanent Hold Display Mode shows either one (in Heat, Cool, or Emergency Heat modes) or both (in Auto mode) temperature setpoints. Adjust the setpoints using the up/down arrow buttons. Navigate between setpoints using the left/right arrow buttons. Press the center button to save changes.

Heat Setpoint (default current Heat Setpoint): valid range: 55°F – Maximum Heating Setpoint Limit (section 5.6.8)

Cool Setpoint (default current Cool Setpoint): valid range: Minimum Cooling Setpoint Limit (section 5.6.8) – 95°F

NOTE: The thermostat forces a 2°F “dead-band” between the Heating and Cooling setpoints. While adjusting the Heating setpoint, the Cooling setpoint may be automatically increased to enforce a 2°F “dead-band”. Likewise, while adjusting the Cooling setpoint, the Heating setpoint may be automatically reduced to enforce a 2°F “dead-band”.

HOLD THIS

TEMPERATURE

UNTIL 5:00 PM

HEAT COOL

70° 74°

CHANGE SET TEMP

PREVIOUS SAVE

HOLD THIS

TEMPERATURE

UNTIL 5:00 PM

HEAT COOL

70° 74°

CHANGE SET TEMP

PREVIOUS SAVE