2.2.3 SHROUD
1.Remove the fan. (Refer to section 2.2.2)
2.Remove the screw which fastens the shroud.
3.Remove the shroud. (See Fig. 9)
4.
2.3 ELECTRICAL PARTS
2.3.1 MOTOR
1.Remove the cabinet. (Refer to section 2.1.2)
2.Remove the clamp cord and disconnect the wire housing in control box. (Refer to section 2.1.3)
3.Remove the turbo fan. (Refer to section 2.2.2)
4.Remove the fan. (Refer to section 2.2.2)
5.Remove the 4 or 2 screws which fasten the motor. (See Fig. 10)
6.Remove the motor.
7.
2.3.2 COMPRESSOR
1.Remove the cabinet. (Refer to section 2.1.2)
2.Discharge the refrigerant system using a FreonTM Recovery System.
If there is no valve to attach the recovery system to, install one (such as a WATCO
3.Disconnect the 3 leads from the compressor.
4.After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections.
5.Remove the 3 nuts and the 3 washers which fasten the compressor. (See Fig. 11)
6.Remove the compressor.
7.
Figure 9
Figure 10
Figure 11
2.3.3 CAPACITOR
1. Remove the control box. (Refer to section 2.1.3)
2. Remove knobs and the tips which fasten the display panel.
3. Disconnect the 2 leads from the rocker switch and remove the panel (Energy saver model only).
4. Remove 2 screws and unfold the control box. (See Fig. 12)
5. Remove the Rotary Switch.
6. Remove the screw and the clamp which fastens the capacitor. (See Fig. 12)
7. Disconnect all the leads on the capacitor terminals.
8.
removal procedures, above. | Figure 12 |
| |
| — 10— |