3.4ELECTRICAL REQUIREMENTS

3.4.1ELECTRICAL DATA (FOR 115V MODEL)

Line Cord Plug

Use Wall Receptacle

Power Supply

 

 

 

 

 

 

 

Do not under any

 

 

 

 

 

 

circumstances cut

Parallel

 

 

 

 

Use 15 AMP time

 

 

 

 

or remove the

 

 

 

 

 

 

grounding prong

type

delay fuse or 15 AMP

from the plug.

 

 

 

 

 

circuit breaker.

 

 

 

 

 

 

Power supply cord with

Standard 125V, 3-wire grounding

 

3-prong grounding plug

receptacle rated 15A, 125V AC

 

 

 

 

 

 

 

 

USE OF EXTENSION CORDS

Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V.

3.4.2 ELECTRICAL DATA (FOR 230/208V MODEL)

Line Cord Plug

Use Wall Receptacle

Power Supply

 

 

 

Do not under any

 

 

 

 

 

 

 

 

circumstances cut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tandem

 

 

 

or remove the

 

 

 

grounding prong

type

 

 

 

 

 

 

from the plug.

 

 

 

 

 

 

 

Power supply cord with

Standard 250V, 3-wire grounding

 

 

3-prong grounding plug

receptacle rated 15A, 250V AC

Use 15 AMP time delay fuse or circuit breaker.

Do not under any

 

 

 

 

 

circumstances cut

 

 

 

 

 

 

 

 

 

 

or remove the

Perpendicular

 

 

 

 

 

 

 

 

grounding prong

type

from the plug.

 

 

 

 

 

Power supply cord with

Standard 250V, 3-wire grounding

3-prong grounding plug

receptacle rated 20A, 250V AC

Use 20 AMP time delay fuse or circuit breaker.

Refer to the nameplate for correct fusing.

All wiring should be made in accordance with local electrical codes and regulations.

NOTE : Aluminum house wiring may pose special problems. Consult a qualified electrician.

3.4.3 ELECTRICAL SAFETY

IMPORTANT GROUNDING INSTRUCTIONS

Air conditioner has a three-prong grounding plug on its power supply cord, which must be plugged into properly grounded three-prong wall receptacle for your protection against possible shock hazard.

FUSE – Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

208, 230, and 208/230 VOLT UNITS

These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged into a matching properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances.

NOTE: DO NOT USE AN EXTENSION CORD on 208, 230, and 208/230 Volt units.

— 22—

Page 22
Image 22
Heat Controller BDE-103 Electrical Requirements, Electrical Data for 115V Model, USE of Extension Cords, Electrical Safety

BD-81, BDE-123, BDE-103, BD-123, BD-101 specifications

The Heat Controller series, including the BD-123, BDE-123, BD-101, BDE-103, and BD-81 models, offers an impressive range of features and innovative technologies designed to provide efficient heating and cooling solutions for a variety of environments. Each model is engineered to stand out in performance, making them suitable for both residential and commercial applications.

The BD-123 model boasts an advanced Energy Efficiency Ratio (EER) that ensures users enjoy reduced energy consumption without compromising comfort. This unit is equipped with an intelligent temperature control system that adapts to the surrounding environment, optimizing heating or cooling as needed. Additionally, its sleek, modern design contributes to both aesthetics and functionality, making it an integral part of any space.

The BDE-123 enhances the functionality of the BD-123 by incorporating smart connectivity options. Users can control the temperature of their space remotely via smartphone applications, allowing for greater convenience and energy management. Furthermore, this model features a filter reminder system that alerts users when it’s time for maintenance, prolonging the unit's lifespan and ensuring peak performance.

The BD-101 model is designed with an emphasis on compactness and versatility. Its lightweight structure allows for easy installation in small spaces, making it ideal for apartments and small offices. With multi-speed fan settings, this model provides customizable airflow, catering to individual preferences and requirements.

The BDE-103 enters the market as a top-tier option, featuring advanced inverter technology. This innovative approach significantly reduces power consumption while maintaining consistent temperature control. The BDE-103 also prides itself on quiet operation, allowing users to enjoy a peaceful atmosphere without the disruptive noise often associated with traditional systems.

Lastly, the BD-81 is tailored for users seeking affordable yet reliable heating and cooling solutions. Despite its lower price point, it does not compromise on quality, offering essential features such as adjustable thermostats and programmable timers. This model makes it accessible for budget-conscious users while still providing comfort and efficiency.

In summary, the Heat Controller BD-123, BDE-123, BD-101, BDE-103, and BD-81 models cater to a variety of needs. With a combination of energy efficiency, smart technology, compact design, and affordability, these models are designed to ensure optimum comfort in any setting while prioritizing user convenience and sustainability. Whether for a small apartment or a large commercial space, there is a Heat Controller model that meets the demands of modern living.