Heat Controller manual DXM2 Service & Application Notes, 1% Sensor Calibration Points

Models: DXM2

1 28
Download 28 pages 2.61 Kb
Page 16
Image 16

Application, Operation, & Maintenance Manual

DXM2 UNIT CONTROLS

Heat Controller, Inc.

DXM2 Service & Application Notes

Pressure Switches

All pressure switches are designed to be normally closed during normal operating conditions, and to open upon fault.

Condensate Sensor – The Condensate Sensor input will fault upon sensing impedance less than 100,000 Ohms for 30 continuous seconds. The recommended design uses a single wire terminated with a male 1/4” quick connect located in the drain pan at desired trip level. Upon a high condensate level the water will short between the air coil and the quick connect producing a resistance less than 100,000 Ohms. Since condensate is free of impurities,

it has no conductivity. Only the impurities from the drain pan and coil dust or dirt create the conductance. A second ground wire with appropriate terminal to the drain pan can be used with the control to replace the air coil ground path. The Condensate Sensor can also essentially be any open contact that closes upon a fault condition.

Thermistor Temperature Sensors – The thermistors used with the DXM2 are NTC (negative temperature coefficient) type. Table 7 shows the replacement part numbers for the LT1 and LT2 thermistors. The sensors have a 1% tolerance and follow the characteristics shown in Table 8. Table 9 shows the nominal resistance at any given temperature and can be used for field service reference. The sensor will use a minimum of 24 awg wire.

Table 8: 1% Sensor Calibration Points

 

Minimum

Maximum

Nominal

Temp (°F)

Resistance

Resistance

Resistance

 

(Ohm)

(Ohm)

(Ohm)

 

 

 

 

78.5

9523

9715

9619

 

 

 

 

77.5

9650

9843

9746

 

 

 

 

76.5

10035

10236

10135

 

 

 

 

75.5

10282

10489

10385

 

 

 

 

33.5

30975

31598

31285

 

 

 

 

32.5

31871

32512

32190

 

 

 

 

31.5

32653

33310

32980

 

 

 

 

30.5

33728

34406

34065

 

 

 

 

1.5

80624

82244

81430

 

 

 

 

0.5

83327

85002

84160

 

 

 

 

0.0

84564

86264

85410

 

 

 

 

Table 9: Nominal resistance at various temperatures

Temp (ºC)

Temp (ºF)

Resistance

Temp (ºC)

Temp (ºF)

Resistance

(kOhm)

(kOhm)

 

 

 

 

-17.8

0.0

85.34

55

131.0

2.99

-17.5

0.5

84.00

56

132.8

2.88

-16.9

1.5

81.38

57

134.6

2.77

-12

10.4

61.70

58

136.4

2.67

-11

12.2

58.40

59

138.2

2.58

-10

14.0

55.30

60

140.0

2.49

-9

15.8

52.38

61

141.8

2.40

-8

17.6

49.64

62

143.6

2.32

-7

19.4

47.05

63

145.4

2.23

-6

21.2

44.61

64

147.2

2.16

-5

23.0

42.32

65

149.0

2.08

-4

24.8

40.15

66

150.8

2.01

-3

26.6

38.11

67

152.6

1.94

-2

28.4

36.18

68

154.4

1.88

-1

30.2

34.37

69

156.2

1.81

0

32.0

32.65

70

158.0

1.75

1

33.8

31.03

71

159.8

1.69

2

35.6

29.50

72

161.6

1.64

3

37.4

28.05

73

163.4

1.58

4

39.2

26.69

74

165.2

1.53

5

41.0

25.39

75

167.0

1.48

6

42.8

24.17

76

168.8

1.43

7

44.6

23.02

77

170.6

1.39

8

46.4

21.92

78

172.4

1.34

9

48.2

20.88

79

174.2

1.30

10

50.0

19.90

80

176.0

1.26

11

51.8

18.97

81

177.8

1.22

12

53.6

18.09

82

179.6

1.18

13

55.4

17.26

83

181.4

1.14

14

57.2

16.46

84

183.2

1.10

15

59.0

15.71

85

185.0

1.07

16

60.8

15.00

86

186.8

1.04

17

62.6

14.32

87

188.6

1.01

18

64.4

13.68

88

190.4

0.97

19

66.2

13.07

89

192.2

0.94

20

68.0

12.49

90

194.0

0.92

21

69.8

11.94

91

195.8

0.89

22

71.6

11.42

92

197.6

0.86

23

73.4

10.92

93

199.4

0.84

24

75.2

10.45

94

201.2

0.81

25

77.0

10.00

95

203.0

0.79

26

78.8

9.57

96

204.8

0.76

27

80.6

9.16

97

206.6

0.74

28

82.4

8.78

98

208.4

0.72

29

84.2

8.41

99

210.2

0.70

30

86.0

8.06

100

212.0

0.68

31

87.8

7.72

101

213.8

0.66

32

89.6

7.40

102

215.6

0.64

33

91.4

7.10

103

217.4

0.62

34

93.2

6.81

104

219.2

0.60

35

95.0

6.53

105

221.0

0.59

36

96.8

6.27

106

222.8

0.57

37

98.6

6.01

107

224.6

0.55

38

100.4

5.77

108

226.4

0.54

39

102.2

5.54

109

228.2

0.52

40

104.0

5.33

110

230.0

0.51

41

105.8

5.12

111

231.8

0.50

42

107.6

4.92

112

233.6

0.48

43

109.4

4.72

113

235.4

0.47

44

111.2

4.54

114

237.2

0.46

45

113.0

4.37

115

239.0

0.44

46

114.8

4.20

116

240.8

0.43

47

116.6

4.04

117

242.6

0.42

48

118.4

3.89

118

244.4

0.41

49

120.2

3.74

119

246.2

0.40

50

122.0

3.60

120

248.0

0.39

51

123.8

3.47

121

249.8

0.38

52

125.6

3.34

122

251.6

0.37

53

127.4

3.22

123

253.4

0.36

54

129.2

3.10

 

 

 

16

Page 16
Image 16
Heat Controller manual DXM2 Service & Application Notes, 1% Sensor Calibration Points, DXM2 UNIT CONTROLS