Heat Controller RAD-183A, RAD-243A 27Room Air Conditioner, Troubleshooting Guide, Fails to Start

Models: RAD-183A RAD-243A

1 38
Download 38 pages 39.8 Kb
Page 27
Image 27
Fails to Start

Troubleshooting Guide

Fails to Start

Check of power source.

Check of control switch setting.

Compressor only fails to start.

Drop of power voltage.

Defect of compressor capacitor.

Capacitor check.

Replacement

Check circuit breaker and fuse.

Gas leakage of feeler bulb of thermostat

Check of control switch.

Fan only fails to start.

Improper wiring.

Improper thermostat setting.

Defect of fan motor capacitor.

Loose terminal connection.

Irregular motor resistance ( 27Room Air Conditioner).

Irregular motor insulation

( Manual background ).

Improper wiring.

Replacement of fan motor.

Irregular motor resistance ( Manual background )

Irregular motor insulation ( Manual background )

Replacement of compressor (Motor damaged)

Regular but fails to start.

Replacement of compressor (locking of rotor, metal).

27Room Air Conditioner

Page 27
Image 27
Heat Controller RAD-183A, RAD-243A service manual 27Room Air Conditioner, Troubleshooting Guide, Fails to Start