Heat Controller RAD-243A, RAD-183A service manual Troubleshooting Guide, Complaint, Cause, Remedy

Models: RAD-183A RAD-243A

1 38
Download 38 pages 39.8 Kb
Page 34
Image 34
Troubleshooting Guide

 

 

Troubleshooting Guide

 

 

 

 

 

COMPLAINT

CAUSE

REMEDY

 

 

 

 

 

Compressor cycles

Capacitor

Test capacitor.

 

on overload.

 

 

 

Wiring

Check the terminals. If loose, repair or replace.

 

 

 

 

 

 

Refrigerating system

Check the system for a restriction.

 

 

 

 

 

Insufficient cooling or heat-

Air filter

If restricted, clean of replace.

 

ing

Exhaust damper door

Close if open.

 

 

Unit undersized

Determine if the unit is properly sized for the area to

 

 

 

be cooled.

 

Excessive noise.

Turbo or fan

Check the set screw or clamp. If loose or missing,

 

 

 

correct. If the blower or fan is hitting air guide,

 

 

 

rearrange the air handling parts.

 

 

 

 

 

 

Copper tubing

Remove the cabinet and carefully rearrange tubing

 

 

 

not to contact cabinet, compressor, shroud, and bar-

 

 

 

rier.

 

Auto air-swing fails.

Rotary switch.

Set the knob to HIGH COOL or LOW COOL while

 

 

 

rocker switch is ON.

 

 

 

 

 

 

Wiring

Check terminals. If loose, repair or replace.

 

 

 

 

 

 

Synchronous motor.

Check the synchronous motor for open circuit.

 

 

 

 

 

Service Manual 34

Page 34
Image 34
Heat Controller RAD-243A, RAD-183A service manual Troubleshooting Guide, Complaint, Cause, Remedy