6 INSTALL THE CASE

IN THE WINDOW (cont.)

DAdjust the leveling bolts and nuts against the outside wall so that the case has a slight tilt to the outside. Tighten nuts with an adjustable wrench. Use a level; about a 1/2 bubble will be the correct case slant to the outside.

EUse a wood block (obtained locally) between the leveling bolts and the wall if the wall is weak or if the weight of the air conditioner falls between the studs in the wall.

FExtend the left and right accordion panels to the vertical window sashes. Drill pilot holes and attach the top and bottom corners with 4 type D screws.

Top mounting rail

Type D

screwType D screw

Type D screw

Type D screw

7

A

B

C

INSTALLSUPPORTBRACKETSBRACKETS

ANDTOP WINDOW FOAM GASKET

THE FOAM TOP WINDOW

GAS KET

Attach the support brackets with two type D screws, one on each side.

Cut the foam top window gasket to the the top window foam gasket to the window

widthindow. width.

Stuff the foam between the glass and the the foam between the glass and the window

towindowprevent toairpreventfrom gettingair intoandtheinsectsroom. from

getting into the room .