Mode Switching Summary
| TEST |
|
|
| Move | |||
|
|
| ||||||
|
|
|
|
|
| to 1, 5, or 20 minutes | ||
|
|
|
|
|
|
|
| |
| AUTO |
|
|
|
|
| Flip light switch | |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| off for one second |
|
|
|
|
|
|
|
| then back on* |
MANUAL MODE |
|
|
| |||||
|
|
|
| |||||
|
|
|
|
*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.
DualBrite® Timer
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the
INSTALLATION
For easy installation, select an existing light operated by a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
CAUTION: Keep the sensor at least 2" (51 mm) away from the lamps.
CAUTION: To Avoid Fire Or Burn Hazards:
•Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.
•Keep fixture at least 2" (51 mm) from combustible materials. Do not aim at objects closer than 3' (1 m).
•Use only T4 100W (max.), G8 tungsten halogen
CAUTION: For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.
For eave mount only:
❒Swing the sensor head towards the clamp screw.
Controls
Clamp Screw
❒Rotate the sensor head clockwise 180° so the controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.