OPERATION
Mode: | Works: Day | Night | |
Test | 5 Seconds | x | x |
Security | 1, 5 or 10 Minutes |
| x |
Manual | Until Dawn* |
| x |
Override |
|
|
|
* resets to Security mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.
MANUAL override MODE
SPECIFICATIONS
Range | Upto70ft.(21m)[varieswith |
| surrounding temperature]. |
Sensing Angle | Up to 180° |
Electrical Load | Up to 300 Watt Maximum |
| Incandescent [Up to 150 |
| Watt maximum each lamp |
| holder] or 10Watt Maximum |
| LED (Up to 5Watt Maximum |
| each lamp holder). |
Bulb Type | Up to 150 Watt Maximum |
| P A R 3 8 T u n g s t e n |
| Incandescent or 5Watt LED |
| model |
Power Requirements .... | 120 VAC, 60 Hz |
Manual Override mode can only be activated at night when the
Flip the light switch off for one sec- ond then back on to change from SECURITY mode to MANUAL OVERRIDE mode.
To return to SECURITY mode, either:
•turn the light off for one minute then turn it on, or...
•daylight will automatically reset the light to SECURITY mode.
1 Second OFF
then...
... back on.
Operating Modes | TEST, SECURITY, and |
| MANUAL OVERRIDE |
1, 5, 10 minutes | |
Test Timer | 5 Seconds |
Manual |
|
Override Timer | Until Dawn |
Range | Adjustable |
Mode Switching Summary
|
| TEST |
|
|
|
| |||
| |||||||||
|
|
|
|
|
| ||||
|
|
|
|
|
| 10 minutes | |||
| SECURITY |
|
|
|
|
|
| ||
|
| AUTO |
|
|
|
|
| ||
| MODE |
|
|
|
|
|
| Flip light switch off | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| for one second then |
MANUAL MODE |
|
|
| back on* | |||||
|
|
|
*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the SECURITY mode.