TESTing AND ADJUSTMENTs
1.Turn on the circuit breaker and light switch.
Note: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on wait 1 1/2 minutes.
2.Turn the RANGE control to the medium position (halfway between MIN and MAX) and the ON- TIME control to the TEST position.
RANGE | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 5 1 TEST
MIN MAX
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the con- trol.
•Nearby large,
| 180° |
8 ft. |
|
(2.4 m) |
|
70 ft. |
|
(21 m) |
|
Maximum Range | Maximum |
| Coverage Angle |
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
MotionMotion
Sensor
Least Sensitive | Most Sensitive |
3. Loosen the clamp screw |
| |
in the sensor ball joint and | Clamp | |
gently rotate the sensor. | ||
Screw | ||
4. Walk through the coverage | ||
| ||
area noting where you are | Ball Joint | |
when the lights turn on (also, |
| |
the LED will flash several |
| |
times when motion is de- |
| |
tected). Move the sensor |
| |
head up, down, or sideways | Aim Sensor | |
to change the coverage | ||
Down for Short | ||
area. Keep the sensor at | ||
Coverage | ||
least 1" (2.5 cm) away from | ||
| ||
the lamps. |
| |
5. Adjust the RANGE as need- |
| |
ed.RANGE set too high may |
| |
increase false triggering. | Aim Sensor | |
6. Secure the sensor head | ||
Higher for Long | ||
by tightening the clamp | ||
Coverage | ||
screw. Do not overtighten | ||
| ||
the screw. |
|
7.Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
3 |