TESTing AND ADJUSTMENTs

TESTing AND ADJUSTMENTs

1.Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on wait 1 1/2 minutes.

2.Turn the RANGE control to the medium position (halfway between MIN and MAX) and the ON- TIME control to the TEST position.

ON-TIME

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the con- trol.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

 

180°

8 ft.

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

MotionMotion

1.Turn on the circuit breaker and light switch. Sensor Bottom of Sensor

Least Sensitive

Most Sensitive

3. Loosen the clamp screw

 

in the sensor ball joint and

Clamp

gently rotate the sensor.

Screw

4. Walk through the coverage

 

area noting where you are

Ball Joint

when the lights turn on (also,

 

the LED will flash several

 

times when motion is de-

 

tected). Move the sensor

 

head up, down, or sideways

Aim Sensor

to change the coverage

Down for Short

area. Keep the sensor at

Coverage

least 1" (2.5 cm) away from

 

the lamps.

 

5. Adjust the RANGE as need-

 

ed.RANGE set too high may

 

increase false triggering.

Aim Sensor

6. Secure the sensor head

Higher for Long

by tightening the clamp

Coverage

screw. Do not overtighten

 

the screw.

 

7.Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Maximum Range WARNING: Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).