5Operation
Priming the Pump (first time use)
1.Set the pump stroke to maximum.
2.Move the pump piston to the fully retracted position.
3.Fill the reservoir with product.
4.Disconnect the
5.Let the product flow to within
6.Cycle the pump.
7.Continue to cycle the pump until
Adjusting Pump Dispense Volume
The black knob on the back of the pump is used to set the stroke of the pump which controls the amount of product dispensed per cycle. The knob should be turned fully clockwise then counter clockwise one full turn. You should then cycle the pump and check to see if the proper amount of product is being dispensed. Continue to adjust the knob until the desired amount is dispensed. Turning the knob clockwise reduces the amount dispensed and turning counterclockwise increases the amount. Plus and minus arrows on the stroke adjustment knob indicate the volume increase and decrease directions.
MORE
STROKE
ADJUSTER
KNOB
LESS
Fig. 3
Adjusting the Amount Dispensed
7