Henny Penny MP-941, MP-944, MP-943 Operation And, Programming, Continued, Special Program Mode

Models: MP-942 MP-941 MP-943 MP-944

1 18
Download 18 pages 2.83 Kb
Page 14
Image 14
3-6. OPERATION AND

Model MP-941/942/943/944

3-6. OPERATION AND

2.

While holding in on the drawer button, press and

PROGRAMMING

 

release the SET button. Now the setpoint temperature

(Continued)

 

will be blinking at a faster rate. Now release the

 

 

drawer button.

 

3.

Press the UP and DOWN buttons to change the

 

 

setpoint temperature.

 

4.

Once the desired setpoint temperature is reached,

 

 

press the SET button to return to normal operation

 

 

mode and the setpoint will be saved.

Special Program Mode

1.Turn the POWER switch off. Press and hold both the UP and DOWN buttons and turn the POWER switch back on. Press and hold the UP and DOWN buttons until “SP” shows on the display, then release the UP and DOWN buttons. Display will now show “°F” or “°C”.

2.Press the UP or DOWN buttons to toggle from “°C” (Celsius), or “°F” (Fahrenheit).

3.Press and release the SET button, and display will show “CAL”. Press and hold the button of the drawer to be calibrated, and use the UP and DOWN buttons to match the display to the actual temperature.

4.After the calibration mode, press and release the SET button to access Initialization Mode.

5.Press and hold either the UP or DOWN button until display reads “In- SYS”. This resets all setpoint temperatures to 180 º F (82º C).

6.After the initialization mode, press and release the SET button the access the Output Test Mode.

7.“OP” will show in the display. Press and release any of the drawer buttons to turn the relays and heaters off and on.

8.After the output test mode, press and release the SET button to access the Display Mode.

9.If “C=y” shows in the display, the time of day shows in the display during normal operation. If “C=n” shows in the display, “ON” shows on the display during normal operation. Press and release the UP and DOWN buttons to toggle from “y” to “n” or vice versa.

10.Press and hold the set button to exit Special Program Mode at any time.

203

3-5

Page 14
Image 14
Henny Penny MP-941, MP-944, MP-943, MP-942 manual Operation And, Programming, Continued, Special Program Mode