| Model |
Setting Control to the Correct Number of Drawers | |
PROGRAMMING | The different models, |
(Continued) | |
| the same control board. The boards are programmed at |
| the factory for the correct unit. But, should the unit show |
| “E06” or some drawers will not heat, the board may not |
| be programmed for the appropriate unit. |
The LED flashes at a fast rate for the drawer(s) not programmed correctly.
To check the drawer programming, turn the unit off, then back on. The display will flash the number of drawers the unit is programmed for. If the unit is not programmed correctly, follow these steps:
|
|
| 1. | Turn the power switch off, then press and hold the |
|
|
|
| SET button and the drawer button, which corresponds |
|
|
|
| to the number of drawers that the unit has, and turn |
|
|
|
| unit back on, ex: |
|
|
| 2. | Release the buttons, and now the unit should be set |
|
|
|
| up for use. |
|
|
|
| Pressing and holding the drawer button shows the |
|
|
|
| temperature of that drawer. If no temperature is |
|
|
|
| displayed, the unit may need to be programmed by |
|
|
|
| the above steps. |
|
|
| ||
| DISPLAY |
| CAUSE | PANEL BOARD CORRECTION |
|
| Control board | Turn switch to OFF position, then turn switch back to | |
|
|
| overheating | ON; if display shows |
|
|
|
| getting too hot; make sure unit is not overheating |
|
|
|
|
|
|
| Faulty temperature | Check to see if unit is set to the correct number of | |
|
|
| probe | drawers, ex: |
|
|
|
| instructions) |
|
|
|
|
|
|
| Memory scrambled | Press and release the UP and DOWN buttons to | |
|
|
|
| initialize the program; if |
|
|
|
| control board |
|
|
|
|
|
| “Hi” |
| Unit overheating; | Have relay or control board replaced |
|
|
| faulty relay or |
|
|
|
| control board |
|
|
|
|
|
|
|
| 203 |