68 Brocade ICX 6650 Administration Guide
53-1002600-01
Diagnostic error codes and remedies for TFTP transfers
3
<mm-dd-yy> is the month, day, and year.
primary | secondary specifies whether the reload is to occur from the primary code flash module or
the secondary code flash module. The default is primary.

Reloading after a specific amount of time

To schedule a system reload to occur after a specific amount of time has passed on the system
clock, use reload after command. For example, to schedule a system reload from the secondary
flash one day and 12 hours later, enter the following command at the global CONFIG level of the
CLI.
Brocade#reload after 01:12:00 secondary
Syntax: reload after <dd:hh:mm> [primary | secondary]
<dd:hh:mm> is the number of days, hours, and minutes.
primary | secondary specifies whether the reload is to occur from the primary code flash module or
the secondary code flash module.

Displaying the amount of time remaining before

a scheduled reload

To display how much time is remaining before a scheduled system reload, enter the following
command from any level of the CLI.
Brocade#show reload

Canceling a scheduled reload

To cancel a scheduled system reload using the CLI, enter the following command at the global
CONFIG level of the CLI.
Brocade#reload cancel
Diagnostic error codes and remedies for TFTP transfers
This section describes the error messages associated with TFTP transfer of configuration files,
software images or flash images to or from a Brocade device.
Error
code
Message Explanation and action
1 Flash read preparation failed. A flash error occurred during the download.
Retry the download. If it fails again, contact customer support.
2Flash read failed.
3 Flash write preparation failed.
4 Flash write failed.
5 TFTP session timeout. TFTP failed because of a time out.
Check IP connectivity and make sure the TFTP server is running.