Brocade ICX 6650 Administration Guide 281
53-1002600-01
Syslog messages A
Informational SNMP Auth. failure, intruder IP: <ip-addr> A user has tried to open a management
session with the device using an invalid
SNMP community string.
The <ip-addr> is the IP address of the host
that sent the invalid community string.
Informational SSH | telnet server enabled | disabled from
console | telnet | ssh | web | snmp session
[by user <username>]
A user ena bled o r disab led an SSH or Telnet
session, or changed the SSH
enable/disable configuration through the
Web, SNMP, console, SSH, or Telnet
session.
Informational startup-confi g was changed
or
startup-config was changed by <user-name>
A configuration change was saved to the
startup-config file.
The <user-name> is the user ID, if they
entered a user ID to log in.
Informational STP: Root Guard Port <port-number>, VLA N
<vlan-ID> consistent (Timeout).
Root guard unblocks a port.
Informational STP: Root Guard Port <port-number>, VLA N
<vlan-ID> inconsistent (Received superior
BPDU).
Root guard blocked a port.
Informational STP: VLAN <vlan id> BPDU-Guard on Port
<port id> triggered (Received BPDU), putting
into err-disable state
The BPDU guard feature has detected an
incoming BPDU on {vlan-id, port-id}
Informational STP: VLAN <vlan id> Root-Protect Port <port
id>, Consistent (Timeout)
The root protect feature goes back to the
consistent state.
Informational STP: VLAN <vlan id> Root-Protect Port <port
id>, Inconsistent (Received superior BPDU)
The root protect feature has detected a
superior BPDU and goes into the
inconsistent state on {vlan-id, port-id}.
Informational STP: VLAN <vlan-id> BPDU-guard port
<port-number> detect (Received BPDU),
putting into err-disable state
STP placed a port into an errdisable state
for BPDU guard.
Informational STP: VLAN 1 BPDU-guard port
<port-number> detect (Received BPDU),
putting into err-disable state.
BPDU guard violation in occurred in STP or
RSTP.
Informational Syslog ser ver <IP-address> deleted | added
| modified from console | telnet | ssh | web
| snmp
OR
Syslog operation enabled | disabled from
console | telnet | ssh | web | snmp
A user made Syslog configuration changes
to the specified Syslog server address, or
enabled or disabled a Syslog operation
through the Web, SNMP, console, SSH, or
Telnet session.
Informational SYSTEM: Optic is not Brocade-qualified
(<port-number>)
Brocade does not support the optical
transceiver.
Informational System: Fan <fan id> (from left when facing
right side), ok
The fan status has changed from fail to
normal.
Informational System: Fan speed changed automatically to
<fan speed>
The system automatically changed the fan
speed to the speed specified in this
message.
Informational System: No free TCAM entry. System will be
unstable
There are no TCAM entries available.
TABLE 57 Brocade Syslog messages (Continued)
Message level Message Explanation