230 Brocade ICX 6650 Administration Guide
53-1002600-01
Digital optical monitoring
9
Syntax: show optic threshold <stack-unit>/<slot>/<port>
Specify the ethernet port in the <stack-unit>/<slot>/<port> format. Stack-unit is 1.
For Temperature, Supply Voltage, TX Bias, TX Power, and RX Power, values are displayed for each of
the following four alarm and warning settings: High alarm, Low alarm, High warning, and Low
warning. The hexadecimal values are the manufacturer internal calibrations, as defined in the
SFF-8472 standard. The other values indicate at what level (above the high setting or below the
low setting) the system should send a warning message or an alarm. Note that these values are
set by the manufacturer of the optical transceiver, and cannot be configured.
Syslog messages for optical transceivers
The system generates Syslog messages for optical transceivers in the following circumstances:
The temperature, supply voltage, TX Bias, TX power, or TX power value goes above or below the
high or low warning or alarm threshold set by the manufacturer.
The optical transceiver does not support digital optical monitoring.
The optical transceiver is not qualified, and therefore not supported by Brocade.
For details about the above Syslog messages, refer to Appendix A, “Syslog messages”.
Brocade#show optic thresholds 1/1/4
Port 1/1/4 optical monitor thresholds:
Temperature High alarm 5a00 90.0000 C
Temperature Low alarm fb00 -5.0000 C
Temperature High warning 5500 85.0000 C
Temperature Low warning 0000 0.0000 C
TX Bias High alarm 1482 10.500 mA
TX Bias Low alarm 04e2 2.500 mA
TX Bias High warning 1482 10.500 mA
TX Bias Low warning 04e2 2.500 mA
TX Power High alarm 4e20 003.0102 dBm
TX Power Low alarm 04ec -008.9962 dBm
TX Power High warning 1edc -001.0237 dBm
TX Power Low warning 0c62 -004.9894 dBm
RX Power High alarm 4e20 003.0102 dBm
RX Power Low alarm 013b -015.0168 dBm
RX Power High warning 1edc -001.0237 dBm
RX Power Low warning 013b -015.0168 dBm