Brocade ICX 6650 Administration Guide
 Brocade ICX 6650 Administration Guide
Title Publication number Summary of changes Date
 Contents
 Chapter Operations, Administration, and Maintenance
 Chapter Ports on Demand Licensing
 Chapter IPv6 Configuration on Brocade ICX 6650 Switch
Full Layer 3 IPv6 feature support
 Chapter Snmp Access
Snmp overview
 FDP configuration
FDP Overview
Displaying FDP information
Clearing FDP and CDP information
 Digital optical monitoring configuration limitations
Setting the alarm interval
Displaying information about installed media
Digital optical monitoring
 Viewing configuration information
Basic system management
Viewing system information
Viewing port statistics
 Local user password changes
NIAP-CCEVS certified Brocade equipment Ironware releases
 Xii Brocade ICX 6650 Administration Guide 53-1002600-01
 Supported hardware and software
Audience
Brocade ICX 6650 slot and port numbering
 Command syntax conventions
Command Option, option Argument, arg Arguments
Document conventions
Text formatting
 Show WWN
 Additional information
Related publications
Brocade resources
 Document feedback
Getting technical help
Other industry resources
 Brocade ICX 6650 slot and port numbering
 Feature
This chapter
Management port overview
How the management port works
 CLI Commands for use with the management port
Syntax show running-config interface management num
Syntax show interfaces management num
Syntax show interfaces brief management num
 Syntax show statistics management num
Logging on through the CLI
Syntax show statistics brief management num
 Online help
Command completion
Scroll control
 Line editing commands
Using slot number, and port number with CLI commands
Ctrl+Key combination Description
 Searching and filtering output from CLI commands
Searching and filtering output from Show commands
CLI nomenclature on Brocade ICX 6650 models
Displaying lines containing a specified string
 Displaying lines starting with a specified string
Searching and filtering output at the --More-- prompt
Results of the search are displayed
 Filtered results are displayed
Using special characters in regular expressions
Character Operation
 Character Operation
 Creating an alias for a CLI command
Configuration notes for creating a command alias
Syntax unalias alias-name
Syntax alias
 Brocade ICX 6650 Administration Guide 53-1002600-01
 Using slot number, and port number with CLI commands
 Basic System Parameters
Basic Port Parameters
 Basic system parameter configuration
 Entering system administration information
Snmp parameter configuration
Basic system parameter configuration
Specifying an Snmp trap receiver
 Specifying a single trap source
Syntax snmp-server host ip-addr0 1 string port value
 Setting the Snmp trap holddown time
Syntax no snmp-server enable traps holddown-time secs
Disabling Snmp traps
Snmp Layer 2 traps
 Disabling Syslog messages and traps for CLI access
Syntax no snmp-server enable traps trap-type
Syntax no enable snmp ve-statistics
Displaying virtual routing interface statistics
 Syntax show logging
Examples of Syslog messages for CLI access
Disabling the Syslog messages and traps
 Syntax no logging enable user-login
Cancelling an outbound Telnet session
Specifying an Sntp server
 Syntax show sntp associations
Syntax no sntp poll-interval
Field Description
 Output from the show sntp associations details command
Syntax show sntp associations details
 Configuring the device as an Sntp server
Configuring the device as an Sntp server
Syntax show sntp status
 Sntp server-mode authentication-key 2 $QHMiR3NzQA=
 Enabling broadcast mode for an Sntp client
Output from the show sntp server-modecommand
Displaying Sntp server information
Syntax show sntp server-mode
 Setting the system clock
Syntax sntp broadcast client
 System time for daylight saving time. command
New start and end dates for US daylight saving time
Syntax sntp sync
Syntax no clock summer-time
 CLI banner configuration
Setting a message of the day banner
Limiting broadcast, multicast, and unknown unicast traffic
Syntax no clock timezone us timezone-type
 Use the no form of the command to disable the requirement
Syntax no banner motd require-enter-key
 Setting a privileged Exec CLI level banner
Local MAC address for Layer 2 management traffic
Syntax no banner execmode delimiting-character
Syntax no banner incoming delimiting-character
 Basic port parameter configuration
Assigning a port name
Syntax no use-local-management-mac
Syntax port-name text
 Port speed and duplex mode modification
Port speed and duplex mode configuration syntax
Basic port parameter configuration
Syntax speed-duplex value
 Syntax no speed-duplex 10g-full 1000-full-master
 Modifying port duplex mode
Port duplex mode configuration syntax
Value can be one of the following Full Half Auto default
Maximum port speed application notes
 Flow control configuration
Flow control configuration notes
Disabling or re-enabling a port
Disabling or re-enabling flow control
 Syntax no flow-control
Negotiation and advertisement of flow control
Syntax no flow-control neg-on
 Symmetric flow control on Brocade ICX 6650 devices
Displaying flow-control status
 1G or 10G ports
About XON and Xoff thresholds
40G ports
 Interpacket Gap IPG on a Brocade ICX 6650 switch
Changing the Gbps fiber negotiation mode
IPG configuration notes
Enabling and disabling symmetric flow control
 Port flap dampening configuration
Port flap dampening configuration notes
Syntax gig-default neg-full-auto auto-gig neg-off
Port priority QoS modification
 Configuring port flap dampening on an interface
Configuring port flap dampening on a trunk
Re-enabling a port disabled by port flap dampening
Displaying ports configured with port flap dampening
 Syslog messages for port flap dampening
Syntax show link-error-disable all
Column Description
 Recovering disabled ports
Port loopback detection configuration notes
Port loop detection
Types of loop detection
 Configuring a global loop detection interval
Configuring the device to automatically re-enable ports
Enabling loop detection
Syntax no loop-detection
 Specifying the recovery time interval
Syntax no errdisable recovery cause loop-detection
Syntax no errdisable recovery interval seconds
Clearing loop-detection
 Syntax show loop-detection resource
Displaying loop detection resource information
FieldDescription
 Syslog message due to disabled port in loop detection
Loop Detection is Enabled
 Basic port parameter configuration
 Operations, Administration, and Maintenance
Feature Brocade ICX 6650
 Software versions installed and running on a device
OAM Overview
Determining the flash image version running on the device
Brocade ICX 6650 devices
 Displaying the boot image version running on the device
Displaying the image versions installed in flash memory
Software versions installed and running on a device
Boot code version is shown in bold type
 Use the following command syntax to verify the flash image
Flash image CLI commands
Flash image verification
 Viewing the contents of flash files
Software upgrades
Image file types
 Using Snmp to upgrade software
Using Snmp to upgrade software
Syntax show dir
Syntax copy flash console filename
 Snmp-server community string ro rw
 Software reboot
Displaying the boot preference
Software boot configuration notes
Software reboot
 Loading and saving configuration files
Loading and saving configuration files
Syntax show boot-preference
 Logging changes to the startup-config file
Syntax no logging enable config-changed
 Copying a configuration file to or from a Tftp server
Dynamic configuration loading
Dynamic configuration usage considerations
Preparing the configuration file
 CLI responds like this
 Following command line will not initiate batch mode
 Loading and saving configuration files with IPv6
Using the IPv6 copy command
Copying a file from the running or startup configuration
Copying a file to an IPv6 Tftp server
 Copying a file to the running or startup configuration
Loading and saving configuration files with IPv6
Copying a file from an IPv6 Tftp server
Copying a file to flash memory
 IPv6 ncopy command
 IPv6 Tftp server file upload
 Using Snmp to save and load configuration information
 Erasing image and configuration files
System reload scheduling
Reloading at a specific time
Syntax reload at hhmmss mm-dd-yyprimary secondary
 Diagnostic error codes and remedies for Tftp transfers
Canceling a scheduled reload
Error Message Explanation and action Code
Reloading after a specific amount of time
 Network connectivity testing
Network connectivity testing
Pinging an IPv4 address
 Network connectivity testing
 Tracing an IPv4 route
 Network connectivity testing
 Feature Brocade ICX
Ports on Demand Overview
 PoD licensing configuration tasks
Ports on Demand terminology
PoD licensing rules
Ports on Demand terminology
 Configuration task Reference
Obtaining a PoD license
 Shows the Software Portal Login window
Brocade Software Portal Login window
 License Management Welcome window
 PoD licensing configuration tasks
 Brocade ICX 6650 Administration Guide 53-1002600-01
 LID
 Shows an example of the license query results
 Transferring a PoD license
Syslog message information
Ports on Demand Licensing
Front panel PoD
 PoD licenses
Rear panel Flexible Ports on Demand
Ports on Demand Licensing
 Enabling ports on the front panel
Ports on Demand Licensing PoD licenses
Trial licenses are not available for PoD licensing
License SKU License Name Function
 Example, the license is copied to unit
Syntax scp licensefileonhost user@IPaddresslicenseunit id
 Deleting a ICX6650-10G-LIC-POD license
Example above, the license is copied to unit
 Syntax show pod
Enabling ports on the rear panel
IPaddress variable is the address of the IPv4 Tftp server
 Syntax no fpod-40g-enable group groupID
 Enter the following command to disable the ports in group
Enable ports for group
Enable ports in group
Disabling the FPoD ports on the rear panel
 Deleting a 10 GbE or 40 GbE license
 Viewing information about PoD licenses
Syntax license delete unit unitid all index licenseindex
 Viewing information about PoD licenses
Displaying general license information for PoD ports
Syntax show license
 Syntax show license unit unitid
Syntax show license unit unitid index indexnumber
 Field Description
 Lic-Used
 Field Description
 40GigabitEthernet1/2/1 is up, line protocol is up
 Viewing information about PoD licenses
 IPv6 Configuration on Brocade ICX 6650 Switch
 IPv6 copy Using the IPv6 copy command on
 Full Layer 3 IPv6 feature support
IPv6 addressing overview
 IPv6 address types
 IPv6 addressing overview IPv6 address types
Address Description Address structure Type
 IPv6 stateless auto-configuration
IPv6 CLI command support
IPv6 command Description Switch code Router code
 Description Switch code Router code
 IPv6 host address on a Layer 2 switch
 Syntax no ipv6 enable
Syntax ipv6 address ipv6-addresslink-local
 Configuring basic IPv6 connectivity on a Layer 3 switch
IPv6 configuration on each router interface
Enabling IPv6 routing
Syntax no ipv6 unicast-routing
 Ospf
 Configuring a link-local IPv6 address on an interface
Configuring basic IPv6 connectivity on a Layer 3 switch
 Configuring an IPv6 anycast address on an interface
Configuring IPv4 and IPv6 protocol stacks
Syntax ip address ip-addresssub-net-masksecondary
 Configuring IPv6 management ACLs
Syntax no ipv6 access-list ACL name
 Restricting Snmp access to an IPv6 node
Configuring Snmp V3 over IPv6
Configuring Sntp over IPv6
Specifying an IPv6 Snmp trap receiver
 IPv6 traceroute
IPv6 Telnet
Establishing a Telnet session from an IPv6 host
 Syntax traceroute ipv6 ipv6-address
Defining an IPv6 DNS entry
Syntax no ipv6 dns domain-name domain name
 Pinging an IPv6 address
 Configuring an IPv6 Syslog server
Viewing IPv6 Snmp server addresses
 Disabling IPv6 on a Layer 2 switch
Static IPv6 route configuration
Disabling router advertisement and solicitation messages
 Configuring a static IPv6 route
 Dest-ipv6-prefix parameter
Parameter Configuration details Status
Prefix-length parameter
 IPv6 over IPv4 tunnel configuration notes
Configuring a manual IPv6 tunnel
IPv6 over IPv4 tunnels
IPv6 over IPv4 tunnels
 Clearing IPv6 tunnel statistics
 Displaying IPv6 tunnel information
Displaying a summary of tunnel information
Displaying tunnel interface information
Syntax clear ipv6 tunnel number
 Displaying interface level IPv6 settings
Syntax show interfaces tunnel number
 Display command above reflects the following configuration
 Ecmp load sharing for IPv6
Ecmp load sharing for IPv6
 Changing the maximum load sharing paths for IPv6
Disabling or re-enabling Ecmp load sharing for IPv6
Displaying Ecmp load-sharing information for IPv6
 IPv6 Icmp feature configuration
Configuring Icmp rate limiting
IPv6 Icmp feature configuration
Syntax ipv6 icmp error-interval interval number-of-tokens
 IPv6 neighbor discovery configuration
IPv6 neighbor discovery configuration
Enabling IPv6 Icmp redirect messages
Syntax no ipv6 redirects
 Neighbor solicitation and advertisement messages
IPv6 neighbor discovery configuration notes
Neighbor discovery is not supported on tunnel interfaces
 Router advertisement and solicitation messages
Neighbor redirect messages
 Setting IPv6 router advertisement parameters
 Here is another example with a specified range
 Prefixes advertised in IPv6 router advertisement messages
 Enabling and disabling IPv6 router advertisements
Setting flags in IPv6 router advertisement messages
Syntax no ipv6 nd suppress-ra
 Configuring reachable time for remote IPv6 nodes
Configuration notes and feature limitations for IPv6 MTU
IPv6 MTU
IPv6 MTU
 Changing the IPv6 MTU
Static neighbor entries configuration
Syntax no ipv6 mtu bytes
 Limiting the number of hops an IPv6 packet can traverse
IPv6 source routing security enhancements
Clearing global IPv6 information
Syntax no ipv6 hop-limit number
 Clearing IPv6 neighbor information
Clearing the IPv6 cache
Clearing global IPv6 information
 Displaying global IPv6 information
Clearing IPv6 routes from the IPv6 route table
Clearing IPv6 traffic statistics
Displaying IPv6 cache information
 Displaying IPv6 interface information
 142 Brocade ICX 6650 Administration Guide 53-1002600-01
 Icmp
 Displaying IPv6 neighbor information
 Displaying the IPv6 route table
 Displaying local IPv6 routers
 Syntax show ipv6 router
Displaying IPv6 TCP information
Port
 Syntax show ipv6 tcp connections
Free TCP = percentage
 General IPv6 TCP connection fields
= percentage
 Location of the TCP
 Syntax show ipv6 traffic
Displaying IPv6 traffic statistics
Field Description IPv6 statistics
 ICMP6 statistics
 Applies to received only
 TCP statistics
 Snmp Access
Snmp overview
 Snmp community strings
Encryption of Snmp community strings
Adding an Snmp community string
Snmp community strings
 Snmp-server community 1 encrypted-string rw
 Displaying the Snmp community strings
Syntax show snmp server
 Configuring your NMS
Configuring Snmp version 3 on Brocade ICX 6650 devices
User-based security model
Defining the engine id
 Defining an Snmp group
Snmp version 3. If you want command
Syntax no snmp-server engineid local hex-string
 Defining an Snmp user account
 162 Brocade ICX 6650 Administration Guide 53-1002600-01
 Syntax system-max view number-of-views
Defining Snmp views
Syntax no snmp-server view name mibtree included excluded
 Snmp version 3 traps
To delete a view, use the no parameter before the command
Snmp version 3 traps
 Defining the UDP port for Snmp v3 traps
Trap MIB changes
 Restricting Snmp Access to an IPv6 Node
Specifying an IPv6 host as an Snmp trap receiver
Snmp v3 over IPv6
Backward compatibility with SMIv1 trap format
 Displaying Snmp Information
Displaying the Engine ID
Displaying Snmp Information
Syntax show snmp engineid
 Displaying Snmp groups
Displaying user information
Interpreting varbinds in report packets
Syntax show snmp group
 Snmp v3 configuration examples
Simple Snmp v3 configuration
More detailed Snmp v3 configuration
Snmp v3 configuration examples
 170 Brocade ICX 6650 Administration Guide 53-1002600-01
 FDP Overview
FDP Overview CDP packets
 FDP configuration
Changing the FDP update timer
Enabling FDP globally
Enabling FDP at the interface level
 Syntax no fdp timer secs
Displaying FDP information
Changing the FDP hold time
Displaying neighbor information
 This line Displays
Entry addresses
 Brocade ICX 6650 Administration Guide 175 53-1002600-01
 Clearing FDP and CDP information
Displaying FDP information for an interface
Displaying FDP and CDP statistics
Clearing FDP and CDP neighbor information
 CDP packets
Enabling interception of CDP packets globally
Enabling interception of CDP packets on an interface
Clearing FDP and CDP statistics
 Displaying CDP information
Displaying neighbors
 Displaying CDP entries
Syntax show fdp entry * device-id
 Clearing CDP information
To clear CDP statistics, enter the following command
Displaying CDP statistics
 Lldp and LLDP-MED
 Lldp terms used in this chapter Supported Lldp features
Lldp terms used in this chapter
 Lldp overview
Illustrates Lldp connectivity
 Benefits of Lldp
LLDP-MED overview
LLDP-MED overview
 Benefits of LLDP-MED
LLDP-MED connectivity
 Lldp transmit mode
General Lldp operating principles
LLDP-MED class
Lldp operating modes
 Lldp receive mode
Lldp packets
 Lldp TLVs
TLV support
Organizationally-specific TLVs
 LLDP-MED TLVs
Mandatory TLVs
Chassis ID
Chassis ID TLV is always the first TLV in the Lldpdu
 Port ID TLV packet format
TTL value
 Syslog messages
MIB support
MIB support TTL TLV format is shown below
 Lldp configuration
Lldp configuration notes and considerations
Lldp configuration
Global task Default behavior / value when Lldp is enabled
 Enabling and disabling Lldp
Changing a port Lldp operating mode
Enabling support for tagged Lldp packets
 Enabling and disabling receive only mode
Enabling and Disabling Transmit Only Mode
 Specifying the maximum number Lldp neighbors per device
Maximum number of Lldp neighbors
Syntax no lldp max-total-neighbors value
 Specifying the maximum number Lldp neighbors per port
Enabling Lldp Snmp notifications and Syslog messages
Syntax no lldp max-neighbors-per-port value
 Changing the minimum time between Lldp transmissions
Syntax no lldp transmit-delay seconds
Syntax no lldp snmp-notification-interval seconds
 Changing the interval between regular Lldp transmissions
Changing the holdtime multiplier for transmit TTL
Syntax no lldp transmit-interval seconds
Syntax no lldp transmit-hold value
 Syntax no lldp reinit-delay seconds
Changing the minimum time between port reinitializations
Lldp TLVs advertised by the Brocade device
General system information for Lldp
 Management Address
 Port description
System capabilities
 System description
 System name
Capabilities
Vlan name
 Untagged Vlan ID
Link aggregation TLV
 MAC and PHY configuration status
 LLDP-MED configuration
LLDP-MED configuration
This section provides the details for configuring LLDP-MED
Maximum frame size
 Default behavior / value
 Changing the fast start repeat count
Syntax no lldp med fast-start-repeat-count value
 Defining a location id
Coordinate-based location
 Example coordinate-based location configuration
Example coordinate-based location advertisement
 Configuring civic address location
Type value elem CA type value elem CA type value
 LLDP-MED configuration Elements used with civic address
 Description Acceptable values / examples Type
 Example civic address location advertisement
Configuring emergency call service
Number variable is a number from 10 to 25 digits in length
 Defining an LLDP-MED network policy
LLDP-MED network policy configuration syntax
Example ECS Elin location advertisements
 216 Brocade ICX 6650 Administration Guide 53-1002600-01
 LLDP-MED attributes advertised by the Brocade device
LLDP-MED capabilities
 Lldp configuration summary
Displaying Lldp statistics and configuration settings
LLDP-MED attributes advertised by the Brocade device
 Displaying Lldp statistics
Syntax show lldp
 Clear lldp statistics all command was issued
Syntax show lldp statistics
 Displaying Lldp neighbors
Syntax show lldp neighbors
 Displaying Lldp configuration details
Displaying Lldp neighbors detail
 Resetting Lldp statistics
 Clearing cached Lldp neighbor information
 Digital optical monitoring configuration limitations
Digital optical monitoring
Enabling digital optical monitoring
Syntax no optical-monitor
 Displaying information about installed media
Setting the alarm interval
Syntax no optical-monitor alarm-interval
 Empty
 Viewing optical monitoring information
Syntax show media slot slot ethernet stack-unit/slot/port
 Viewing optical transceiver thresholds
Status value Description
 Syslog messages for optical transceivers
Syntax show optic threshold stack-unit/slot/port
 Syslog
 About Syslog messages
Displaying Syslog messages
 Enabling real-time display of Syslog messages
Enabling real-time display for a Telnet or SSH session
Syntax no logging console
Syntax terminal monitor
 Syslog service configuration
Displaying the Syslog configuration
Syslog service configuration
Displaying real-time Syslog messages
 Static and dynamic buffers
Field Definition
 Time stamps
Clearing log entries
Syntax clear logging dynamic-buffer static-buffer
 Brocade ICX 6650 Administration Guide 237 53-1002600-01
 To specify a Syslog server, enter the logging host command
Disabling or re-enabling Syslog
Specifying a Syslog server
Syntax no logging on udp-port
 Specifying an additional Syslog server
Disabling logging of a message level
Changing the number of entries the local buffer can hold
Syntax no logging buffered level num-entries
 Changing the log facility
Local buffer configuration notes
Syntax logging facility facility-name
 Displaying TCP or UDP port numbers in Syslog messages
Displaying interface names in Syslog messages
Syntax no Ip show-portname
 Syslog reboot configuration considerations
Retaining Syslog messages after a soft reboot
Clearing the Syslog messages from the local buffer
 Basic system management
Viewing system information
 Viewing configuration information
Syntax show version
 Viewing port statistics
Syntax show option
Syntax show statistics ethernet stack-unit/slot/port
Port statistics
 Parameter Description
Basic system management Port statistics
Statistics
 Viewing STP statistics
 Clearing statistics
Syntax clear option
 Viewing egress queue counters
Syntax show interface ethernet stack-unit/slot/port
 Rmon support
Maximum number of entries allowed Rmon control table
Clearing the egress queue counters
Syntax clear statistics ethernet stack-unit/slot/port
 Statistics Rmon group
Rmon support
Syntax show rmon statistics ethernet stack-unit/slot/port
ParameterDefinition
 Rmon support Export configuration and statistics
Parameter Definition
 History Rmon group
Alarm Rmon group
Event Rmon group
 SFlow
SFlow version
 Extended router information
SFlow support for IPv6 packets
Extended gateway information
 SFlow configuration considerations
IPv6 packet sampling
SFlow and hardware support
SFlow and CPU utilization
 SFlow and source port
Configuring and enabling sFlow
SFlow and sampling rate
 Specifying an sFlow collector on IPv4 devices
Specifying the collector
Syntax no sflow destination ip-addrdest-udp-port
 Changing the polling interval
Changing the sampling rate
Specifying an sFlow collector on IPv6 devices
Syntax no sflow destination ipv6 ip-addrdest-udp-port
 Configuration considerations
Configured rate and actual rate
Change to global rate
Module rate
 Changing the default sampling rate
Syntax no sflow sample num
Changing the sampling rate of a module
Changing the sampling rate on a port
 Changing the sampling rate for a trunk port
 Command syntax for enabling sFlow forwarding
Enabling sFlow forwarding
Changing the sFlow source port
Syntax no sflow source-port num
 SFlow version 5 feature configuration
Syntax no sflow enable Syntax no sflow forwarding
 Specifying the sFlow version format
Specifying the sFlow agent IP address
Specifying the version used for exporting sFlow data
Syntax no sflow agent-ip ipv4-addr
 Specifying the maximum flow sample size
Syntax no sflow version 2
Syntax no sflow max-packet-size size
Syntax no sflow export system-info
 Displaying sFlow information
Enabling the sFlow agent to export CPU-directed data
Syntax no sflow export cpu-traffic
Specifying the sampling rate for exported CPU-directed data
 Syntax show sflow
 SFlow SFlow information
Clearing sFlow statistics
Syntax clear statistics
 Utilization list for an uplink port
Utilization list for an uplink port command syntax
Utilization list for an uplink port
 Displaying utilization percentages for an uplink
Syntax show relative-utilization num
 272 Brocade ICX 6650 Administration Guide 53-1002600-01
 Brocade Syslog messages
Message Explanation
Fan num, location , failed
Mac-address on portnum
 Syslog messages Brocade Syslog messages
 PCI-config-register-offset
PCI-bus-number, Dev
PCI-device-number, Reg Offset
Addr memory-address
 Message level Explanation
Level shutdown-degrees C degrees
From session-id
Username from session-id filter
 User username from session-id
Root ID root-id
 Stp-state
 Vlan-id
 MAC address any
MAC address any, dst mac = Destination
IP=ipaddr
 Port-number
Fan speed
 Unit/slot/port to
Unit/slot/port on VLANs vlan-id to Vlan-id
Unit/slot/port on vlan-id
Unit/slot/port on Vlan vlan-id
 Mac-address MgmtPriChg
Mac-address MsgAgeExpiry
Vlan vlan-id interface portnum STP
Mac-address RootPort portnum
 Portnum
DOT1X Port portid Mac macaddress
 Rid router-id, intf addr ip-addr
Macaddress on port portid
State ospf-state
 286 Brocade ICX 6650 Administration Guide 53-1002600-01
 Pkt type pkt-type
 Ip-addr, pkt type type
Type
 Rid router-id, limit num
LSA id lsa-id, LSA rid lsa-router-id
Area area-id, LSA type lsa-type
 Ospf-state
 Brocade ICX 6650 Administration Guide 291 53-1002600-01
 Interface configuration error has occurred
 Rid router-id, area area-id
Nbr ip-addr, state ospf-state
 Rid router-id, nbr addr ip-addr
 Mac-address
State vrrp-state
Mac-addr interface portnum
 List ACL-num denied ip-proto
Ethernet portnum mac-addr
Eportnum, address mac-address
Portnum src macaddr mac-addr
 Chassis temperature has risen above the warning level
 298 Brocade ICX 6650 Administration Guide 53-1002600-01
 NIAP-CCEVS certified Brocade equipment Ironware releases
Local user password changes
Brocade product Brocade IronWare Discussed Software version
 300 Brocade ICX 6650 Administration Guide 53-1002600-01
 Index
 Lldp advertise mac-phy-config-status ports
Lldp enable receive ports
Ipv6 nd prefix-advertisement,134
Clear fdp table, 176
 Brocade ICX 6650 Administration Guide 303 53-1002600-01
 FDP
 Icmp
 131
 LLDP-MED
 266
 Snmp
 SSH
 XON and Xoff thresholds
 312 Brocade ICX 6650 Administration Guide 53-1002600-01