228 Brocade ICX 6650 Administration Guide
53-1002600-01
Digital optical monitoring
9
Vendor: BROCADE Version: A
Part# : 57-0000075-01 Serial#: AAF209450000A9K
Port 1/1/10: Type : 10GE LR 10km (SFP +)
Vendor: BROCADE Version: A
Part# : 57-0000076-01 Serial#: ADF209100000D4P
Port 1/1/11: Type : 1G M-SX(SFP)
Vendor : Brocade Version:
Part# : AFBR-5715PZ-FD Serial#: AA0910S4YAF
Port 1/1/12: Type : 1G M-SX(SFP)
Vendor : Brocade Version:
Part# : AFBR-5710PZ-FD Serial#: AM0850SCTHH
Use the show media ethernet command to obtain information about the media device installed in a
port.
Brocade#show media ethernet 1/2/1
Port 1/2/1: Type : 40GE-SR4 100m (QSFP+)
Vendor: BROCADE Version: A
Part# : 57-1000129-01 Serial#: ATA111491001893
Syntax: show media [slot <slot> | ethernet <stack-unit>/<slot>/<port>]
Specify the ethernet port in the <stack-unit>/<slot>/<port> format. Stack-unit is 1.
Viewing optical monitoring information
You can view temperature and power information for qualified SFP, SFP+, and QSFP+ transceivers
installed in a Brocade ICX 6650 device.
Use the show optic command to view information about an SFP, SFP+, and QSFP+ transceivers
installed in a particular port. The following shows example output from a 40GBASE-SR4 fiber optic.
The fiber optic has 4 channels for TX, RX.
Optical monitoring feature will not work in the following scenarios:
The port is DOWN.
The the optic module does not support optical monitoring.
Brocade(config)#show optic 1/2/1
40GBASE_SR4
===============
Port Temperature Voltage Rx Power Tx Bias Current
+----+-----------+--------------+--------------+---------------+
1/2/1 42.6640 C 005.1911 dBm -001.1560 dBm 7.332 mA
Normal Normal Normal Normal
Chan Rx Power #1 Rx Power #2 Rx Power #3 Rx Power #4
+----+-----------+--------------+--------------+---------------+
-001.1560 dBm -001.0846 dBm -001.3507 dBm -001.1221 dBm
Normal Normal Normal Normal
Chan Tx Bias #1 Tx Bias #2 Tx Bias #3 Tx Bias #4
+----+-----------+--------------+--------------+---------------+
7.332 mA 7.412 mA 7.208 mA 7.222 mA
Normal Normal Normal Normal
Syntax: show optic <stack-unit>/<slot>/<port>
Specify the ethernet port in the <stack-unit>/<slot>/<port> format. Stack-unit is 1.