9

Digital optical monitoring

 

 

 

 

Vendor: BROCADE

Version: A

 

Part#

:

57-0000075-01

Serial#: AAF209450000A9K

 

Port 1/1/10: Type

:

10GE LR 10km (SFP +)

 

Vendor:

BROCADE

Version: A

 

Part#

:

57-0000076-01

Serial#: ADF209100000D4P

 

Port 1/1/11: Type

:

1G M-SX(SFP)

Version:

 

Vendor : Brocade

 

Part#

: AFBR-5715PZ-FD

Serial#: AA0910S4YAF

 

Port 1/1/12: Type

:

1G M-SX(SFP)

Version:

 

Vendor : Brocade

 

Part# : AFBR-5710PZ-FD

Serial#: AM0850SCTHH

Use the show media ethernet command to obtain information about the media device installed in a port.

Brocade#show

media

ethernet 1/2/1

(QSFP+)

Port 1/2/1: Type

: 40GE-SR4 100m

 

Vendor: BROCADE

Version: A

 

Part#

: 57-1000129-01

Serial#: ATA111491001893

Syntax: show media [slot <slot> ethernet <stack-unit>/<slot>/<port>]

Specify the ethernet port in the <stack-unit>/<slot>/<port>format. Stack-unit is 1.

Viewing optical monitoring information

You can view temperature and power information for qualified SFP, SFP+, and QSFP+ transceivers installed in a Brocade ICX 6650 device.

Use the show optic command to view information about an SFP, SFP+, and QSFP+ transceivers installed in a particular port. The following shows example output from a 40GBASE-SR4 fiber optic. The fiber optic has 4 channels for TX, RX.

Optical monitoring feature will not work in the following scenarios:

The port is DOWN.

The the optic module does not support optical monitoring.

Brocade(config)#show optic 1/2/1

 

 

40GBASE_SR4

 

 

 

===============

Voltage

Rx Power

Tx Bias Current

Port

Temperature

+

----+

-----------+

--------------+

--------------+

---------------+

1/2/1

42.6640 C

005.1911 dBm -001.1560 dBm

7.332 mA

 

 

Normal

Normal

Normal

Normal

+

Chan Rx Power #1

Rx Power #2

Rx Power #3

Rx Power #4

----+

-----------+

--------------+

--------------+

---------------+

 

-001.1560 dBm

-001.0846 dBm

-001.3507 dBm

-001.1221 dBm

 

 

Normal

Normal

Normal

Normal

+

Chan

Tx Bias #1

Tx Bias #2

Tx Bias #3

Tx Bias #4

----+

-----------+

--------------+

--------------+

---------------+

 

 

7.332 mA

7.412 mA

7.208 mA

7.222 mA

 

 

Normal

Normal

Normal

Normal

Syntax: show optic <stack-unit>/<slot>/<port>

Specify the ethernet port in the <stack-unit>/<slot>/<port>format. Stack-unit is 1.

228

Brocade ICX 6650 Administration Guide

 

53-1002600-01

Page 246
Image 246
Brocade Communications Systems 6650 manual Viewing optical monitoring information