A Syslog messages

TABLE 57 Brocade Syslog messages (Continued)

Message level

Message

Explanation

Alert

Temperature <degrees> C degrees, warning

 

level <warn-degrees>C degrees, shutdown

 

level <shutdown-degrees> C degrees

Indicates an over temperature condition on the active module.

The <degrees> value indicates the temperature of the module.

The <warn-degrees>value is the warning threshold temperature configured for the module.

The <shutdown-degrees> value is the shutdown temperature configured for the module.

Critical

Authentication shut down <portnum> due to

 

DOS attack

Denial of Service (DoS) attack protection was enabled for multi-device port authentication on the specified <portnum>, and the per-second rate of RADIUS authentication attempts for the port exceeded the configured limit. The Brocade device considers this to be a DoS attack and disables the port.

Debug

BGP4: Not enough memory available to run

 

BGP4

The device could not start the BGP4 routing protocol because there is not enough memory available.

Debug

DOT1X: Not enough memory

There is not enough system memory for

 

 

802.1X authentication to take place.

 

 

Contact Brocade Technical Support.

Error

No of prefixes received from BGP peer

 

<ip-addr>exceeds maximum

 

prefix-limit...shutdown

The Layer 3 Switch has received more than the specified maximum number of prefixes from the neighbor, and the Layer 3 Switch is therefore shutting down its BGP4 session with the neighbor.

Informational

IPv6: IPv6 protocol disabled on the device

IPv6 protocol was disabled on the device

 

from <session-id>

during the specified session.

 

 

 

Informational

IPv6: IPv6 protocol enabled on the device

IPv6 protocol was enabled on the device

 

from <session-id>

during the specified session.

 

 

 

Informational

MAC Filter applied to port <port-id>by

Indicates a MAC address filter was applied

 

<username> from <session-id> (filter

to the specified port by the specified user

 

id=<filter-ids> )

during the specified session.

 

 

<session-id>can be console, telnet, ssh,

 

 

web, or snmp.

 

 

<filter-ids>is a list of the MAC address

 

 

filters that were applied.

Informational

MAC Filter removed from port <port-id>by

 

<username> from <session-id> (filter

 

id=<filter-ids> )

Indicates a MAC address filter was removed from the specified port by the specified user during the specified session.

<session-id>can be console, telnet, ssh, web, or snmp.

<filter-ids>is a list of the MAC address filters that were removed.

276

Brocade ICX 6650 Administration Guide

 

53-1002600-01

Page 294
Image 294
Brocade Communications Systems 6650 manual Message level Explanation, Level shutdown-degrees C degrees, From session-id