276 Brocade ICX 6650 Administration Guide
53-1002600-01
Syslog messages
A
Alert Temperature <degrees> C degrees, warning
level <warn-degrees> C degrees, shutdown
level <shutdown-degrees> C degrees
Indicates an over temp erature condit ion on
the active module.
The <degrees> value indicates the
temperature of the module.
The <warn-degrees> value is the warning
threshold temperature configured for the
module.
The <shutdown-degrees> value is the
shutdown temperature configured for the
module.
Critical Authentication shut down <portnum> due to
DOS attack
Denial of Service (DoS) attack protection
was enabled for multi-device port
authentication on the specified <portnum>,
and the per-second rate of RADIUS
authentication attempts for the port
exceeded the configured limit. The Brocade
device considers this to be a DoS attack
and disables the port.
Debug BGP4: Not enough memory available to run
BGP4
The device could not start the BGP4 routing
protocol because there is not enough
memory available.
Debug DOT1X: Not enough memory There is not enough system memory for
802.1X authentication to take place.
Contact Brocade Technical Support.
Error No of prefixes received from BGP peer
<ip-addr> exceeds maximum
prefix-limit...shutdown
The Layer 3 Switch has received more than
the specified maximum number of prefixes
from the neighbor, and the Layer 3 Switch is
therefore shutting down its BGP4 session
with the neighbor.
Informational IPv6: IPv6 protocol disabled on the device
from <session-id>
IPv6 protocol was disabled on the device
during the specified session.
Informational IPv6: IPv6 protocol enabled on the device
from <session-id>
IPv6 protocol was enabled on the device
during the specified session.
Informational MAC Filter applied to port <port-id> by
<username> from <session-id> (filter
id=<filter-ids> )
Indicates a MAC address filter was applied
to the specified port by the specified user
during the specified session.
<session-id> can be console, telnet, ssh,
web, or snmp.
<filter-ids> is a list of the MAC address
filters that were applied.
Informational MAC Filter removed from port <port-id> by
<username> from <session-id> (filter
id=<filter-ids> )
Indicates a MAC address filter was removed
from the specified port by the specified user
during the specified session.
<session-id> can be console, telnet, ssh,
web, or snmp.
<filter-ids> is a list of the MAC address
filters that were removed.
TABLE 57 Brocade Syslog messages (Continued)
Message level Message Explanation