Appendix

Syslog messages

A

 

 

 

Table 57 lists all of the Syslog messages. Note that some of the messages apply only to Layer 3 Switches.

NOTE

This chapter does not list Syslog messages that can be displayed when a debug option is enabled.

The messages are listed by message level, in the following order, then by message type:

Emergencies (none)

Alerts

Critical

Errors

Warnings

Notifications

Informational

Debugging

TABLE 57

Brocade Syslog messages

 

 

 

 

Message level

Message

Explanation

 

 

 

Alert

<num-modules>modules and 1 power

Indicates that the chassis needs more

 

supply, need more power supply!!

power supplies to run the modules in the

 

 

chassis.

 

 

The <num-modules>parameter indicates

 

 

the number of modules in the chassis.

 

 

 

Alert

Fan <num>, <location>, failed

A fan has failed.

 

 

The <num> is the fan number.

 

 

The <location> describes where the failed

 

 

fan is in the chassis.

 

 

 

Alert

MAC Authentication failed for

RADIUS authentication was successful for

 

<mac-address> on <portnum>

the specified <mac-address>on the

 

 

specified <portnum>; however, the VLAN

 

 

returned in the RADIUS Access-Accept

 

 

message did not refer to a valid VLAN or

 

 

VLAN ID on the Brocade device. This is

 

 

treated as an authentication failure.

 

 

 

Alert

MAC Authentication failed for

RADIUS authentication failed for the

 

<mac-address> on <portnum> (Invalid User)

specified <mac-address>on the specified

 

 

<portnum> because the MAC address sent

 

 

to the RADIUS server was not found in the

 

 

RADIUS server users database.

Brocade ICX 6650 Administration Guide

273

53-1002600-01

 

Page 291
Image 291
Brocade Communications Systems 6650 manual Brocade Syslog messages, Message Explanation, Fan num, location , failed