Brocade ICX 6650 Administration Guide 275
53-1002600-01
Syslog messages A
Alert Power supply <num>, <location>, failed A power supply has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the chassis.
Alert System: Module in slot <slot-num>
encountered PCI config read error: Bus
<PCI-bus-number>, Dev
<PCI-device-number>, Reg Offset
<PCI-config-register-offset>.
The module encountered a hardware
configuration read error.
Alert System: Module in slot <slot-num>
encountered PCI config write error: Bus
<PCI-bus-number>, Dev
<PCI-device-number>, Reg Offset
<PCI-config-register-offset>.
The module encountered a hardware
configuration write error.
Alert System: Module in slot <slot-num>
encountered PCI memory read error: Mem
Addr <memory-address>
The module encountered a hardware
memory read error.
The <memory-address> is in hexadecimal
format.
Alert System: Module in slot <slot-num>
encountered PCI memory write error: Mem
Addr <memory-address>.
The module encountered a hardware
memory write error.
The <memory-address> is in hexadecimal
format.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI bridge
validation failure. Module will be deleted.
The module encountered an unrecoverable
(hardware) bridge validation failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI config read
failure. Module will be deleted.
The module encountered an unrecoverable
hardware configuration read failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI config write
failure. Module will be deleted.
The module encountered an unrecoverable
hardware configuration write failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI device
validation failure. Module will be deleted.
The module encountered an unrecoverable
(hardware) device validation failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI memory
read failure. Module will be deleted.
The module encountered an unrecoverable
hardware memory read failure. The module
will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI memory
write failure. Module will be deleted.
The module encountered an unrecoverable
hardware memory write failure. The module
will be disabled or powered down.
Alert System: No Free Tcam Entry available.
System will be unstable
In FWS devices, the limit for the TCAM
routing entries has been reached. You must
reboot the device.
Alert System: Temperature is over shutdown level,
system is going to be reset in <num>
seconds
The chassis temperature has risen above
shutdown level. The system will be shut
down in the amount of time indicated.
TABLE 57 Brocade Syslog messages (Continued)
Message level Message Explanation