Syslog messages

A

TABLE 57

Brocade Syslog messages (Continued)

 

 

 

 

 

 

Message level

Message

Explanation

 

 

 

 

 

Alert

Power supply <num>, <location>, failed

A power supply has failed.

 

 

 

The <num> is the power supply number.

The <location> describes where the failed power supply is in the chassis.

Alert

System: Module in slot <slot-num>

 

encountered PCI config read error: Bus

 

<PCI-bus-number>, Dev

 

<PCI-device-number>, Reg Offset

 

<PCI-config-register-offset>.

The module encountered a hardware configuration read error.

Alert

System: Module in slot <slot-num>

 

encountered PCI config write error: Bus

 

<PCI-bus-number>, Dev

 

<PCI-device-number>, Reg Offset

 

<PCI-config-register-offset>.

The module encountered a hardware configuration write error.

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered a hardware

 

 

 

encountered PCI memory read error: Mem

 

memory read error.

 

 

 

Addr <memory-address>

 

The <memory-address>is in hexadecimal

 

 

 

 

 

format.

 

 

 

 

 

 

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered a hardware

 

 

 

encountered PCI memory write error: Mem

 

memory write error.

 

 

 

Addr <memory-address>.

 

The <memory-address>is in hexadecimal

 

 

 

 

 

format.

 

 

 

 

 

 

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered an unrecoverable

 

 

 

encountered unrecoverable PCI bridge

 

(hardware) bridge validation failure. The

 

 

 

validation failure. Module will be deleted.

 

module will be disabled or powered down.

 

 

 

 

 

 

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered an unrecoverable

 

 

 

encountered unrecoverable PCI config read

 

hardware configuration read failure. The

 

 

 

failure. Module will be deleted.

 

module will be disabled or powered down.

 

 

 

 

 

 

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered an unrecoverable

 

 

 

encountered unrecoverable PCI config write

 

hardware configuration write failure. The

 

 

 

failure. Module will be deleted.

 

module will be disabled or powered down.

 

 

 

 

 

 

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered an unrecoverable

 

 

 

encountered unrecoverable PCI device

 

(hardware) device validation failure. The

 

 

 

validation failure. Module will be deleted.

 

module will be disabled or powered down.

 

 

 

 

 

 

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered an unrecoverable

 

 

 

encountered unrecoverable PCI memory

 

hardware memory read failure. The module

 

 

 

read failure. Module will be deleted.

 

will be disabled or powered down.

 

 

 

 

 

 

 

Alert

 

System: Module in slot <slot-num>

 

The module encountered an unrecoverable

 

 

 

encountered unrecoverable PCI memory

 

hardware memory write failure. The module

 

 

 

write failure. Module will be deleted.

 

will be disabled or powered down.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alert

System: No Free Tcam Entry available.

In FWS devices, the limit for the TCAM

 

 

 

 

System will be unstable

 

routing entries has been reached. You must

 

 

 

 

 

 

reboot the device.

 

 

 

 

 

 

 

 

 

Alert

 

System: Temperature is over shutdown level,

 

The chassis temperature has risen above

 

 

 

system is going to be reset in <num>

 

shutdown level. The system will be shut

 

 

 

seconds

 

down in the amount of time indicated.

Brocade ICX 6650 Administration Guide

275

53-1002600-01

 

Page 293
Image 293
Brocade Communications Systems 6650 manual PCI-bus-number, Dev, PCI-device-number, Reg Offset, PCI-config-register-offset