Message table (continued)

 

 

 

 

 

 

 

 

 

 

Indicator display

The ON indicator, LAMP indicator and TEMP indicator will light or

 

 

 

 

 

 

 

 

blink in the following cases.

 

 

 

 

 

 

 

 

 

 

 

 

 

ON indicator

LAMP indicator

 

TEMP indicator

Meaning

 

Remedy

 

 

 

 

 

 

 

 

 

 

Lights orange

Goes off

 

Goes off

Standby mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinks green

Goes off

 

Goes off

During warming up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights green

Goes off

 

Goes off

During operation *1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinks orange

Goes off

 

Goes off

During cooling down

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool projector by power off for 45

 

Lights red

Lights red

 

Goes off

Lamp cannot light

minutes.

 

 

If the indicator is still it, lamp may be

 

 

 

 

 

 

 

 

 

 

 

 

defective. Replace.

 

 

 

 

 

 

 

 

 

 

Lights red

Blinks red

 

Goes off

Lamp is not inserted or the

Securely insert the lamp or close the

 

 

lamp door open

lamp door.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights red

Goes off

 

Lights red

Temperature inside too hight

Correctly reinstall so as not to block

 

 

ventilation holes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights red

Goes off

 

Blinks red

Cooling fan accidented

Call a maintenance person.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accumulated lamp operation

Replace lamp and reset the

 

Blinks red

Blinks red

 

Goes off

time has exceeded 2,000

accumulated lamp operation time.

 

 

 

 

 

hours

(See page 28, 29)

 

 

 

 

 

 

 

 

 

 

When the LAMP indicator lights, turn the power off. If the problem cannot be recovered, contact your dealer.

*1 Even when the indicator lights green, if the power supply section becomes too hot , the lamp may be automatically turned off to cool it down (indicator continues to light green). In this case, turn off the power switch and allow the unit to cool down before turning the power switch on again. The lamp will light. If the lamp does not light because it is still automatically turned off, contact your dealer.

*2 When inside temperature becomes high because ventilation holes are blocked, normally, TEMP indicator will light red. However, to protect the projector, the lamp may be turned off and at this time LAMP indicator may light red.

When you think something wrong

Check the following again before asking for service. If the trouble cannot be recovered, consult your dealer.

Phenomena

Cause

 

Check point

Page

 

 

 

 

Power cannot be

The Main power is not turned on.

Turn the MAIN POWER switch on.

P.12

The power cord is disconnected.

Insert the power cord into an AC socket.

P.8

turned on.

60 seconds have not elapsed since the

When the power is turned off turn the power

P.12

 

power was turned off.

switch on after waiting at least 60 seconds.

 

No picture and

The setting of the input source is not

Set the correct input using the input select

P.7, 9,

correct.

button of the projector or the remote control.

12, 16

sound

Wiring to the projector is not correct.

Connect the cable correctly.

P.8, 26

 

 

 

 

 

Only picture is

Wiring to the projector is not correct.

Connect the cable correctly.

P.8, 26

The volume is set to minimum.

Press the VOL button or press the MENU button

P.9, 15

displayed with no

 

and adjust the volume.

 

sound

 

 

The unit enters the mute mode.

Press the MUTE button.

P.7, 9

 

Only sound is

Wiring the projector is not correct.

Connect the cable correctly.

P.8, 26

The brightness is set fully to the dark

Press the MENU button and select BRIGHT and

P.15

heard without a

side.

press the

button.

 

picture

 

Lens cap is attached.

Remove the lens cap.

P.12

 

 

 

 

 

Color is weak and

The color and tint have been adjusted

Adjust the color and tint correctly.

P.15

tint is incorrect

incorrectly.

 

 

 

 

The brightness and contrast has been

Adjust the brightness and contrast correctly.

P.15

Picture is dark

adjusted incorrectly.

 

 

 

 

The lamp has not been adjusted.

Replace the lamp with a new one.

P.28

 

 

 

 

Picture is not clear

Focus or H.PHASE is not matched.

Adjust the focus or H.PHASE

P.12, 15

 

 

 

 

LAMP indicator

Trouble with the lamp.

Turn off the power and leave for 45 minutes ;

P.30

lights red.

then turn the power on again.

 

 

TEMP indicator

 

Do not block the venational holes.

P.5

Inside the projector too hot.

Clean the air filter.

P.27

lights red.

 

Use the projector under 35°C temperature.

 

 

 

 

 

 

 

 

Remote control

Cable was connected after the power

Be sure to perform procedure in the following order:

 

(1)Connect cable. (2)Turn on projector. (3)Turn PC on.

 

mouse cannot be

was turned on.

 

Input video signal and select and display input

 

operated.

Video signal not selected.

 

source.

 

 

 

 

 

 

 

 

 

 

 

30 A bright dot may be seen in the picture. This is a phenomenon peculiar to the liquid crystal and is not a problem.

Page 30
Image 30
Hitachi CP-S830W/E specifications When you think something wrong