TROUBLESHOOTING (continued)

TROUBLESHOOTING (continued)

Indicators Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.

Table 10. Indicators Message

STANDBY/ON

LAMP

TEMP

Contents

indicator

indicator

indicator

 

 

 

 

 

Lights

Turns off

Turns off

The Standby mode has been set.

orange

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Warming up. Please wait.

green

 

 

 

 

 

 

 

Lights

Turns off

Turns off

ON. Normal operation possible.

green

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Cooling. Please wait.

orange

 

 

 

 

 

 

 

 

 

 

Lamp is not lit.

 

 

 

The interior of the equipment may be too hot. Switch

 

 

 

power OFF, wait 20 minutes until the equipment cools,

Lights red

Lights

Turns off

and check whether the ventilation openings are

 

red

 

blocked, whether the air filter is dirty, or whether the

 

 

 

ambient temperature exceeds 35 °C. And switch power

 

 

 

ON again. Replace the lamp if the same problem

 

 

 

occurs.

 

 

 

 

 

 

 

Lamp or lamp cover is not found, or hasn’t been fitted in

 

 

 

correctly.

Lights red

Blinks

Turns off

Switch power OFF, and wait for 45 minutes until the

 

red

 

equipment cools. Check fitting of the lamp and lamp

 

 

 

cover, and switch power ON again. Contact your dealer

 

 

 

if the same problem occurs again.

 

 

 

 

 

 

 

The cooling fan is not operating.

 

 

Blinks

Switch power OFF, and wait for 20 minutes until the

Lights red

Turns off

equipment cools. Check for foreign matters in the fan,

red

 

 

and switch power ON again. Contact your dealer if the

 

 

 

 

 

 

same problem occurs again.

 

 

 

 