RS-232C Communication (continued)

Communicaion settings

1. Protocol

19200bps,8N1

2. Command format ("h" shows hexadecimal)

Byte Number

0

1

2

3

4

5

6

7

8

9

10

11

12

Command

 

 

Header

 

 

 

 

 

 

Data

 

 

 

Header

 

Data

CRC

Action

Type

Setting

 

code

Packet

size

 

flag

code

Action

 

 

 

 

 

L

H

 

L

H

L

H

L

H

L

H

L

H

<SET>Change setting to desired value [(cL)(cH)] by [(eL)(eH)].

<GET>Read projector internal setup value [(bL) (bH)] .

<INCREMENT> Increment setup value [(bL)(bH)] by 1.

<DECREMENT> Decrement setup value [(bL)(bH)] by 1.

<EXECUTE> Run a command [(bL)(bH)].

BEh EFh

03h

 

 

(aL)

(aH)

01h

00h

(bL)

(bH)

(cL)

(cH)

 

 

 

 

 

 

 

 

 

 

 

 

(aL)

(aH)

02h

00h

(bL)

(bH)

00h

00h

06h

00h

 

 

 

 

 

 

 

 

(aL)

(aH)

04h

00h

(bL)

(bH)

00h

00h

 

 

 

 

 

 

 

 

 

 

 

 

(aL)

(aH)

05h

00h

(bL)

(bH)

00h

00h

 

 

 

 

 

 

 

 

 

 

 

 

(aL)

(aH)

06h

00h

(bL)

(bH)

00h

00h

 

 

 

 

 

 

 

 

 

 

[Header code] [Packet] [Data size]

Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 ~ 4.

[CRC flag]

For byte number 5, 6, refer to RS-232C Communication / Network command table (&17).

[Action]

Set functional code to byte number 7, 8.

<SET> = [01h, 00h], <GET> = [02h, 00h], <INCREMENT> = [04h, 00h] <DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]

Refer to the Communication command table (&above).

[Type] [Setting code]

For byte number 9 12, refer to RS-232C Communication / Network command table (&17).

9

Downloaded from www.Manualslib.com manuals search engine

Page 9
Image 9
Hitachi CP-X2510N, CP-X3010N user manual Communicaion settings, Protocol