Connection to the control signal terminal (continued)

 

 

 

 

Control data table

 

Item

Data code

 

 

 

 

 

MOUSE

00h=stop mouse emulation. 01 7Fh=start mouse emulation

 

 

 

 

 

 

COMMUNICATE

0Xh=8N1

 

 

 

 

 

1Xh=7N1

 

 

 

 

 

X0h=1200bps, X1h=2400bps, X2h=4800bps, X3h=9600bps, X4h=19200bps

 

 

 

POWER

1Eh=Power off (Standby mode), 1Fh=Power on

 

 

 

ZOOM

01-3Fh=Zoom +, 41-7Fh=Zoom- 01, 04 (up) 3F, 7F (down)

 

 

FOCUS

01-3Fh=Focus +, 41-7Fh=Focus- 01, 04 (short) 3F, 7F (long)

 

 

MIRROR

00h=Normal, 01h=H:Invert, 02h=V:Invert, 03h=H & V:Invert

 

 

 

INPUT

11h=VIDEO1, 12h=VIDEO2, 21h=RGB1, 22h=RGB2

 

 

 

 

VIDEO SYSTEM

00h

00h=Auto, 00h 01h=NTSC, 00h 04h=NTSC4.43

 

00h

02h=PAL, 00h 03h=SECAM, 00h 05h=M-PAL

 

 

 

 

 

VOLUME

00h (min) 7Fh (max)

 

 

 

 

 

 

MUTE

00h=Mute off, 01h=Mute on

 

 

 

 

 

 

 

 

BRIGHT

00h

00h

00h

(dark) 00h 00h 7Fh (brite)

 

 

 

 

 

 

 

CONTRAST

00h

00h

00h

(lower) 00h 00h 7Fh (higher)

 

 

 

 

 

 

 

COLOR

00h

00h

20h

(less) 00h 00h 60h (more)

 

 

 

 

 

 

TINT

00h

00h

2Eh (red) 00h 00h 52h (green)

 

 

 

 

 

 

 

SHARPNESS

00h

00h

00h

(soft) 00h 00h 64h (sharp)

 

 

 

 

 

 

 

H.PHASE

00h

00h

00h 00h 00h 1Fh

 

 

 

 

 

 

 

 

 

H.POSIT

00h

00h

52h

00h (left) 00h

00h 54h 04h (right)

 

 

 

 

 

 

H.SIZE

00h

00h

00h

06h (narrow) 00h 00h 48h 0Bh (wide)

 

 

 

 

 

 

V.POSIT

00h

00h

06h

00h (down) 00h 00h 50h 05h (up)

 

 

 

 

 

 

BLANK

0Xh=Blank off

 

 

 

 

1Xh=Blank on

 

 

 

 

bit0 0=Blue off, 1=Blue on,

bit1 0=Green off,

1=Green on

 

bit2 0=Red off, 1=Red on,

bit3 0=Not change,

1=Change

 

 

REVEAL

X1h=Reveal down, X4h=Reveal right, X=0 (slow) 7 (fast)

 

 

 

 

 

 

 

Caution If computer sends the undefined command code or data code, Projector can not guarantee operation.

Command is consisted of 2 command bytes and following data bytes. 1-st byte indicates the kinds of commands and the length of command.

‘0xH’ : Error-reply

Projector sends to computer.

‘1xH’ : Command reply

Projector sends to computer.

‘2xH’ : Ask command

Computer sends to Projector.

‘3xH’ : Set command

Computer sends to Projector.

‘4xH’ : Default set command

Computer sends to Projector.

‘5xH’ — ‘FxH’ : Reserved

‘x’ indicates the length of data bytes.

2-nd byte indicates the command code ‘yy’ as command table. Data table shows the data byte.

25

Page 25
Image 25
Hitachi CP-X955W/E specifications Control data table