Hitachi HSU-12RD03/R2(SDB) Outdoor unit, Installation of Outdoor Unit, Connection of pipes

Models: HSU-09RD03/R2(SDB) HSU-12RD03/R2(SDB)

1 39
Download 39 pages 2.81 Kb
Page 8
Image 8
Outdoor unit

Outdoor unit

1.Installation of Outdoor Unit

Install according to Drawing for the installation of indoor and outdoor units

2.Connection of pipes

1.Installation of Outdoor UnitTo bend a pipe, give the roundness as large as possible not to crush the pipe ,and the bending radius

should be 30 to 40 mm or longer.

2.Connection of pipes Connecting the pipe of gas side first makes working easier. Half union The connection pipe is specialized for R410A.

Half union

Flare nut

Torque wrench

Spanner

Forced fastening without careful centering may damage the threads and cause a leakage of gas.

Pipe Diameter

Fastening torque

Liquid side 6.35mm(1/4")

18N.m

Gas side 9.52mm(3/8")

42N.m

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.

The standard pipe length is 5m. If it is over 5m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant.

B

Outdoor unit

Outdoor unit

Indoor unit

A

A

 

Outdoor unit

 

B

B

Oil trap

 

Indoor unit

A

Indoor unit

 

 

CAUTION

In case A is more than 5m

Max.Elevation: Amax=10m

Max. Length: Bmax=15m

In case the elevation A is more than 5m,

In case the pipe length B is more than 10m,

oil trap shoud be installed every 5~7m

the refrigerant should be charged, according to 20 g/m.

3.Connection

Flare nut Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws.

Torque wrench Insert the cable according to terminal number in the same manner as the indoor unit.

3.Connection If wiring is not correct, proper operation can not be carried out and controller may be damaged.

4.Attaching Drain-Elbow Fix the cable with a clamp.

4.Attaching Drain-Elbow

Manual background If the drain-elbow is used, please attach it as figure. (Note: Only for heat pump unit.)