13. Ext trigger

The external trigger function is used with a frame grabber to obtain an image of an object at a desired exposure time. Settings can provide images at various timings. The exposure time can be controlled by the external trigger pulse width.

1) Trigger mode : Selects external trigger mode Mode 1: Use for exposure time less than 2 fields.

Mode 2: Use for exposure time greater than 2 fields.

Note: Longer integration time tends to show increased noise and flaws in the CCD.

2) Delay time : Time from end of trigger pulse to camera sync reset

Setting range is 2 to 20 H. Can be used with a strobe light source to provide an optimum image with a frame grabber.

3)Trig polarity : Selects positive or negative trigger pulse polarity.

4)WE polarity : Selects WE pulse polarity

Selects pulse (WE) output synchronized to image obtained from the camera rear panel multi connector for 1 field or 1 frame. Use to match the interface of an external frame grabber or other equipment.

The trigger and CCD mode timing can be combined to obtain image timing as indicated in the figures.



a) MODE: MODE1, CCD MODE: FLD

 

 

 

 

 

 

 

 

 

more than 64

s

 

 

 

 

 

 

 

 

more than 2 fields

 

 

 

 

 

TRIGGER POLARITY:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITEVE

External trigger pulse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRIGGER POLARITY:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEGATEVE

Exposure time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video signal output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ODD

EVEN

 

 

 

 

 

 

 

ODD

EVEN

 

 

 

 

W E POLARITY:

 

SYNC reset

 

 

SYNC reset

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITEVE

 

 

 

 

 

 

 

 

 

W E pulse output

 

 

 

 

 

 

 

 

W E POLARITY:

 

 

 

 

 

 

 

 

 

 

 

 

NEGATEVE

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 











27